IPC1601&2602&5602&5603
User Guide
7 Alarm Configuration
Issue 12 (2014-06-12)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
50
Parameter
Description
Setting
Frequency
Frequency of the pulse generated by the
device when the device receives I/O alarm
signals.
NOTE
This parameter is valid only when the square
wave alarm input mode is used.
[Setting method]
Enter a value manually.
[Default value]
0
Alarm Time
Alarm output duration. The value
0
indicates that the alarm remains valid.
NOTE
This parameter is valid only when the square
wave alarm input mode is used.
[Setting method]
Enter a value manually.
[Default value]
0
[Value range]
0 to 86400 seconds
Manual Control
Control the alarm output.
-
Step 3
Click
OK
.
The message " Linkage I/O Parameter Updated
!
Updated" is displayed.
Step 4
Click
OK
.
The system automatically saves the settings.
----End
7.2 Setting I/O Alarm Linkage Parameters
Preparation
The PTZ linkage policy is applicable only to a camera with the PTZ or connected to an
external PTZ.
Description
Alarm linkage refers to linkage alarm output and camera PTZ linkage. Alarm output including
alarm generation by the external alarm device connected to the camera alarm output port,
alarm email sending, and alarm information output. When receiving an alarm from the alarm
input port, the camera performs linkage alarm output and enables PTZ linkage based on the
preceding parameters, and rotates based on the linkage policy.
On the
I/O Alarm Linkage
page, you can perform the following operations:
Enable the I/O alarm function.
Configure the I/O alarm schedule.
Configure the alarm output channel.
Configure the PTZ linkage policy.