IPC1601&2602&5602&5603
User Guide
3 Hardware Installation
Issue 12 (2014-06-12)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
10
----End
Installing a CS-Mount Manual Aperture and Manual focus Lens
Before installing a lens, remove the front protection cap from the camera first.
Step 1
Use the Phillips screwdriver to loosen the screw on the side of the focusing ring.Fully turn the
focusing ring counterclockwise and manually bring the camera into focus.
The camera has been calibrated before delivery. You can also adjust the focusing ring as required to
obtain the required focus.
Step 2
Tighten the screw using the Phillips screwdriver to secure the focusing ring.
Step 3
Attach the lens to the camera body and turn the lens clockwise until it locks into place.
----End
3.2.3 Uninstalling a Lens
Step 1
Turn the lens counterclockwise until it is removed.
Step 2
Remove the cable plug of the auto aperture lens from the IRIS port.
If you are removing a manual aperture lens, skip Step 2.
Step 3
If no lens needs to be installed on the camera, mount the front protection cap to protect the
device.
----End
3.3 Connecting Other Devices to the Camera Through the
Ports on the Rear Panel
Figure 3-2 shows how to connect other devices to the camera through the ports on the rear
panel.