Name
Definition
Function
Button pressing
Press the button for less
than 1s.
iBOX blinking function
Button pressing
Press and hold the
button for more than 1s
but less than 5s.
Creates a network if no network has
been created. Switches between network
organization and data transmission if a
network has been created.
Button holding
down
Press and hold the
button for more than 10s
but less than 20s.
Clears the current network (including
the network parameters of all the online
iBATs).
Default Button
Table 2-12
Default button description
Name
Definition
Function
Default button
Press and hold the
button for more than 10s
but less than 20s.
Reset to the default IP address
(192.168.0.10).
2.2 iBAT
The iBAT is a battery monitoring module that supports 12 V power input and monitors the
voltages, internal resistances, and pole temperatures of batteries.
Features
Monitors the voltages, internal resistances, and pole temperatures of batteries.
Uploads battery data to iBOX through wireless communication.
Has the hibernation function:
−
When the battery supply voltage is lower than 9.6 V for more than 30 minutes, the
iBAT automatically powers off.
−
When the iBAT has failed in communication for more than 30 minutes, it
automatically powers off.
−
When the iBAT has not been networked successfully more than two days after
power-on, it automatically powers off (when the battery voltage is higher than 2.18
V/cell for 10 minutes, the iBAT will start again).
−
After networking is complete, when the iBAT detects that the battery voltage is
lower than 12.6 V for 50 hours, the iBAT automatically powers off.
Supports the serial port function. For details, contact Huawei technical support.