Networking Requirements
, hosts of the accounting department are located in a VLAN. Hosts of
the accounting department are attacked by viruses when they access the Internet. The attacked
hosts send a large number of broadcast packets, causing broadcast storms in the VLAN. Even
hosts cannot communicate. The company requires that broadcast storms be prevented to ensure
communication between hosts and information security.
Figure 1-3
Networking diagram of intra-VLAN proxy ARP
PC A
PC B
VLAN 10
Ethernet0/0/0
Router
100.1.1.100/24
100.1.1.10/24
Accounting Department
Configuration Roadmap
The configuration roadmap is as follows:
1.
Configure port isolation on the downstream interface of the Router to forbid Layer 2
communication and remove broadcast storms.
2.
Enable intra-VLAN proxy ARP on the VLANIF interface to prevent broadcast storms and
Layer 3 communication between hosts in the accounting department.
Data Preparation
To complete the configuration, you need the following data:
l
Interface connecting the Router and the accounting department: Ethernet0/0/0
l
ID of the VLAN that Ethernet0/0/0 joins: VLAN 10
l
IP address of VLANIF10: 100.1.1.12/24
Procedure
Step 1
Add Ethernet0/0/0 to VLAN 10.
# Create VLAN 10.
<Huawei>
system-view
[Huawei]
sysname Router
[Router]
vlan 10
Huawei AR150&200 Series Enterprise Routers
Configuration Guide - IP Service
1 ARP Configuration
Issue 02 (2012-03-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
30