81
82
LP-532 REV. 8.13.2014
LP-532 REV. 8.13.2014
Main components Replacement Instructions
6. Gas valve
1. Close the gas shut off valve
2. Turn the power off
3. Disconnect all electrical connection to the gas
valve
4. Disconnect the gas line from the gas valve by
loosing the nuts as shown.
5. Loosen fours screws to separate gas valve from
upper bracket
6. Loosen fours screws to separate gas valve from
lower bracket
7. Replace gas valve with new component.
8. Assembly is in the reverse order as the part was
repaired.
9. Open the gas shut off valve
10. Turn the power on
11. Turn the unit on and ensure proper operation.
NOTE:
You must check for gas leaks around gas
valve assembly. failure to do so will result in death
or serious personal injury.
Chapter 5 Replacement instructions
Main components Replacement Instructions
7. Condensate Trap
1. Close the gas shut off valve
2. Turn the power off
3. Removed condensate trap drain cap and ensure
it is drained properly.
4. Loosen two screws to open the front cover.
5. Remove hose inlet hocse from the HX
condensate pan connected to condensate trap.
6. Remove hose that connect connected from APS
to condensate trap.
7. Loosen 3 screws on the bottom of the cabinet
that holds condensate trap in place.
8. Replace condensate trap with new component.
9. Assembly is in the reverse order as the part was
repaired.
10. Open the gas shut off valve
11. Turn the power on
12. Turn the unit on and ensure proper operation.
Chapter 5 Replacement instructions
WARNING
Failure to turn the power and gas off to the
appliance before repair could result in serious
injury or death.