5
6
LP-532 REV. 8.13.2014
LP-532 REV. 8.13.2014
Model Name
RT-199
Gas Input Rate
MAX
199,000 Btu/h
MIN
19,900 Btu/h
Hot Water Capacity
35°F Rise
11.0 Gal
45°F Rise
8.5 Gal
77°F Rise
5.0 Gal
Installation
Indoor, Wall Hung, Fully Condensing
Flue System
Sealed Combustion Direct Vent
Vent Run
2” (15 ft), 3″(100ft) Schedule 40 PVC, CPVC, PP
Orifice Size
NG(Orifice/Needle)
9.5 mm (0.374˝) / 9.5 mm (0.374˝)
LP(Orifice/Needle)
Consult the factory
Gas Supply Pressure
NG
3.5˝ WC to 14˝ WC
LP
3.5˝ WC to 14˝ WC
Manifold Pressure
Min (3″)
NG: -0.01”WC, LP: -0.11” WC
Max (3″)
NG: -0.03”WC, LP: -0.09” WC
Power Supply
Main Supply
120V 60Hz
Maximum
Power Consumption
135W
Ignition System
Direct Electronic Ignition / Automatic Flame Sensing
Burner System
Single Orifice Premixed Fuel Modulation Metal Fiber
Infrared
Gas Valve System
Air ratio valve
Minimum Flow Rate
0.5 GPM
Internal Pipe Material
Stainless Steel
Dimensions
W17.3 ″ – H27.6 ″ – D14.8 ″
Weight
88 lbs
Sub Heat Exchanger Water Capacity (DHW)
Under 2 Gallon
Control Panel / Main Controller
P-920C / GTH-9500C
Water Pressure
Min 15 - Max 150 PSI
Connection Sizes
Cold Water Inlet /
Hot Water Outlet
3/4″NPT
Gas Inlet
3/4″NPT
Materials
Casing
Cold Rolled Carbon Steel
Heat Exchanger
Primary Heat Exchanger : Stainless Steel
Secondary Heat Exchanger : Stainless Steel
Safety Devices
Flame Rod, Burner Overheat Cut Off Device (302F/150C),
Gas Leak Detector, Exhaust High Limit Switch
(149F/65C), Freeze Protection Ceramic Heater (turns on
at 41F/5C, turns off at 59F/15C), Water temperature limit
switch (199F/93C).
Chapter 1 Product Characteristics