21
22
LP-532 REV. 8.13.2014
LP-532 REV. 8.13.2014
Description/Part #
Jumper Wire Connection / 7850P-096
Check Point
(Main PCB)
CN 11
Function
This part is used to jump out circuit
Failure Event
Jumper is disconnected.
Effects
Th unit shuts down.
Error Code
Er 42
Diagonostic
① Make sure the jumper is properly connected.
Color / Wire Number
Jumped wire connection (white) : connector ⑥,⑭
Description/Part #
Gas Leak Detection Sensor /
7850P-093
Check Point
(Main PCB)
N/A
Function
This senosr shutsdown the unit if gas leak is detected
Failure Event
Gas leak detection sensor is not operating properly
Effects
Risk of explosion and personal injury
Error Code
Er 40
Diagonostic
① Follow instruction on the first page of the manual. Check for leakage around the gas
valve and gas piping by using soapy water.
② Check the burner assembly
Color / Wire Number
N/A
① ② ③ ④ ⑤ ⑥ ⑦ ⑧
⑨
⑩
⑪ ⑫ ⑬ ⑭ ⑮
⑯
Chapter 2 Components description
Chapter 2 Components description
CN11