5.5.1. While
testing
After starting a test, the instrument allows displaying in real time both the parameters set
and the current state of the operation.
1. Use the arrow keys or select the icon “Saved Data Management” in the GENERAL
MENU.
2. With a recording in progress, press the
ENTER
key or touch the icon “Saved Data
Management” on the display. The instrument displays the following screen:
Fig. 103: Screen with information about recording in progress with PV system set
3. The screen above contains the following information:
Recording autonomy of the instrument with selections made in Days/Hours
Comments inserted in the relevant comment field of section “Analyzer setting” (see §
5.4.2.1).
Type, data and hour when recording started
Type of recording stop (always manual)
The Integration Period set
The number of integration periods made in real time
The type of photovoltaic system considered
If the parameters of SOLAR-0x (Irradiation, Cell Temperature, Environmental
Temperature) are being recorded
The type of clamp used
The full scale selected for the clamps used
4. Press the
ESC
key (or smart icon ) to exit the information screen.
CAUTION
Only section “Measure display” is available while testing. The instrument
displays the message “
Menu not available while recording
” in case of
selection of other sections. Stop testing by pressing the
F1
key.
The
ON/OFF
key is disabled while testing. The instrument shows the
message “
Recording in progress. Function not available
”. Stop testing by
pressing the
F1
key.