Operator's Manual
B 235 Evo
129
By pressing the
key you can quit the programme without making the calibration.
18. MESSAGES ON THE DISPLAYS
The machine can recognise a certain number of malfunction conditions and signals them
to the user by visualising the relevant messages on the displays.
– A – Notice Messages
A 3
wheel not suitable for performing the sensitivity calibration, use a wheel of
average dimensions (typically 5.5”X14”) or larger, but NOT exceeding a weight
of 40kg.
A 5
Incorrect dimension settings for an ALU programme. Correct the set dimen-
sions.
A 7
The machine is temporarily unable to select the requested programme.
Perform a wheel spin, then repeat the request.
A 10
Internal sensor not in the rest position. Return the sensor to the rest position
(completely in). If the message does not disappear, internal sensor operation
can be disabled by pressing the
button.
A 20
Ultrasonic sensor calibration template in an incorrect position during calibra-
tion. Bring it to the position indicated, then repeat the calibration.
Bring it to the position indicated and repeat the calibration.
A 26
Programme available only after selecting one of the following programmes:
ALU 1P / ALU 2P / Motorcycle Dynamic / Motorcycle ALU or if selected in the
Motorcycle Programme but with the wheel NOT in the centred position.
A 41
Incorrect wheel spin procedure on the wheel balancer without guard. The
warning appears when the spin button is pressed for more than 10 seconds
without pressing the "START" key at the same time. Release the button and
spin the wheel according to the procedure indicated in the "Wheel Spin"
paragraph.
If the problem persists, contact the technical support centre.
A Stp
Wheel stop during the spin phase.
Wheel movement is not integral with swinging unit movement: Check correct
wheel tightening.
A Cr
Spin performed with the guard raised.
Lower the guard to perform the wheel spin.
In machine versions with a start button, either the START key or the button
released during the spin.
Perform the spin holding down both the START key as well as the button.