120
Operator's Manual
B 235 Evo
- press the
key to confirm
- use the
keys to search for Gr 5 (if the gram display mode is activated)
or Oun 0.25 (if the ounce display mode is activated)
- press the
key to change the setting:
or Gr 1 to activate the unbalance display rounded to the gram
or Gr 5 to activate the unbalance display rounded to the nearest multiple of five
If the ounce display mode is active
or Oun 0.25
to activate the unbalance display rounded to a quarter of an ounce
or Oun 0.10
to activate the unbalance display rounded to a tenth of an ounce
- press the
key to confirm and exit.
15.4. AUTOMATIC POSITION SEARCH (RPA)
When the automatic position search programme is activated, at the end of every balancing
spin the machine stops the wheel in the position for applying the outer side weight; if it is
equal to zero, the wheel is stopped in the inner side weight application position.
Press the
button to search for the second side position with the guard raised.
Proceed as follows to deactivate the automatic position search programme:
- Press the
key.
- use the
keys to search for SEt UP
- press the
key to confirm
- use the
keys to search for rPA on (or rPA oFF if previously set)