5) Confirm the user authentication of the disk array system using Storage Management
Software. See
“About errors attributable to disk array systems” (page 133)
◦
6) Check the RSG of HG for the import destination server.
•
(2) An error occurred when an operation command was given to the disk array system.
See
“About errors attributable to disk array systems” (page 133)
E2002058
Message
Serial number: [serial number]: unable to unmask LU: [LU#] to local server: [iSCSI initiator name]
LU mapping failed.
Explanation
Recommended action
•
(1) Using Storage Management Software, perform the following operation:
1) When the maximum number of LUs re- mapped to the target in which the iSCSI
initiator of the import server for S-VOL is registered, delete any LUs which is not used.
◦
◦
2) When the number of targets has reached the maximum, delete the host groups which
are not used.
•
(2) An error occurred when an operation command was given to the disk array system.
See
“About errors attributable to disk array systems” (page 133)
E200205A
Message
Unable to retrieve the Array object information.
Explanation
Cannot retrieve the storage information corresponding to the specified serial number.
Recommended action
•
(1) Confirm whether HORCM starts.
•
(2) Confirm that the FC cables are connected properly.
•
(3) Confirm that the contents of hiRaidcomX.config are correct.
•
(4) Confirm the serial number of the disk array system and the user name using Storage
Management Software. Then, type the proper serial number, user name, and password into
the Add Storage dialog box, and register the disk array system.
•
(5) Confirm the path definition of the command device.
•
(6) Confirm and perform the followings using Storage Management Software.
•
(7) Confirm that the host mode setting of the host group has been set to Windows. If the
setting has been set to other than Windows, set it to Windows.
E200205C
Message
Abort Snapshots occurred.
120
Troubleshooting
Summary of Contents for XP
Page 51: ...5 Missing number 51 ...