E200201F
Message
Unable to create the P-Vol S-Vol pair.
Explanation
Pair creation of Business Copy failed.
Recommended action
•
(1) Create the S-VOL after P-VOL formatting is complete.
•
(2) Confirm that a free space of the specified RAID/Parity group or THP (Smart) pool is
sufficient.
•
(3) MU number which can be used to create Business Copy pair may have already been
used. Check the target P-VOL pair configuration and keep available MU.
•
(4) Confirm that the target LU is not LUSE volume (LUSE volume is not supported).
•
(5) An error occurred when an operation command was given to the disk array system.
See
“About errors attributable to disk array systems” (page 133)
E2002020
Message
LU#' of Delete S-Vol # 'S-VOL failed. Please retry the operation.
Explanation
Deletion of an S-VOL failed.
Recommended action
•
(1) Refresh or restart the GUI tool, then re-execute the remove of the S-VOL.
•
(2) When the pair status of the S-VOL is Split Pending, wait for the pair status to become
PSUS. Alternately, set the pair status to PAIR using Storage Management Software and
then re-execute.
•
(3) Confirm the valid/invalid setting of the Password Protection function using Storage
Management Software. If it is valid, change it to invalid.
•
(4) Using Storage Management Software, confirm that LU to be removed exists in the disk
array system.
•
(5) Check that it does not come into conflict with the operational restrictions and points of
consideration when using RAID Manager. See Table 2.5.2-3.
•
(6) Refer to the VSS Provider log files, when another Error message is output, and execute
the corresponding solutions.
•
(7) An error occurred when a pair operation command was given to the disk array system.
See
“About errors attributable to disk array systems” (page 133)
E2002021
Message
Resyc S-Vol # 'LU#' failed. Please retry the operation.
Error messages
109
Summary of Contents for XP
Page 51: ...5 Missing number 51 ...