[XP7]
•
(1) In the case of virtual DKC, if Host group name: HP-VSS-HG does not exist in RSG which
P-VOL belongs to, create HP-VSS-HG.
•
(2) If virtual DKC is running, confirm the setting when VSS provider is used in the virtual
DKC. See Table 9-1.
•
(3) If the virtual DKC which straddles multiple physical DKCs is used, make sure that the
virtual LDEV ID of P-VOL is not duplicated in the virtual DKC. If the virtual LDEV ID of P-VOL
is duplicated, assign the virtual LDEV ID of P-VOL to prevent duplication.
E200201C
Message
The LU is not found.
Explanation
While waiting for format completion, S-VOL is not found.
Recommended action
During S-VOL creation, operation might have been interrupted by Storage Management Software
or another program, and the P-VOL or S-VOL may have been deleted or the pair state may have
been changed. Confirm the existence of P-VOL and S-VOL and check the pair status using
Storage Management Software.
E200201D
Message
DeleteLun failed for S-Vol: [LU number of S-VOL].
Explanation
Could not delete an S-VOL.
Recommended action
An error occurred when an operation command was given to the disk array system.
See
“About errors attributable to disk array systems” (page 133)
E200201E
Message
Initializing S-Vol LU failed.
Explanation
Initialization of an S-VOL failed.
Recommended action
•
(1) During S-VOL creation, operation might have been interrupted by other program, and
the P-VOL or S-VOL may have been deleted or the pair state may have been changed.
Confirm the existence of P-VOL and S-VOL and check the pair status using Storage
Management Software.
•
(2) An error occurred when an operation command was given to the disk array system.
See
“About errors attributable to disk array systems” (page 133)
108
Troubleshooting
Summary of Contents for XP
Page 51: ...5 Missing number 51 ...