109
Core Switch 2/64 and SAN Director 2/128 installation guide
11.
If the switch configuration does not replicate correctly, download the backup configuration:
a.
Enter the
switchDisable
command to disable the switch.
b.
Enter the
configDownload
command and enter the requested information.
c.
After the configuration has been downloaded, enter the
switchEnable
command.
swDir:admin> configshow ”fabric”
fabric.domain:2
fabric.ficonmode:0
fabric.ididmode:0
fabric.ops.BBCredit:16
fabric.ops.E_D_TOV:2000
fabric.ops.R_A_TOV:10000
fabric.ops.dataFieldSize:2112
fabric.ops.mode.fcpProbeDisable:0
fabric.ops.mode.isolate:0
fabric.ops.mode.longDistance:0
fabric.ops.mode.noClassF:0
fabric.ops.mode.pidFormat:1
fabric.ops.mode.tachyonCompat:0
fabric.ops.mode.unicastOnly:0
fabric.ops.mode.useCsCtl:0
fabric.ops.mode.vcEncode:0
<remaining output not shown>
swDir:admin>
Summary of Contents for StorageWorks 2/64 - Core Switch
Page 8: ...Contents 8 ...
Page 24: ...Overview 24 ...
Page 130: ...Setting up and installing modems 130 ...
Page 134: ...Running routine operations 134 ...
Page 166: ...Index 166 ...