background image

 

Hardware options installation  70 

7.

 

Open the slot cover retainer and remove the PCIe blank. 

 

8.

 

Install the dedicated iLO management port module and close the slot cover. 

 

9.

 

Install the system air baffle (on page 

24

). 

10.

 

If removed, install the PCI air baffle ("

Install the PCI air baffle

" on page 

22

). 

11.

 

Install the access panel (on page 

19

). 

12.

 

Return the server to an upright position. 

13.

 

Connect each power cord to the server. 

14.

 

Connect each power cord to the power source. 

15.

 

Power up the server (on page 

18

). 

 

Summary of Contents for ProLiant ML110 Gen9

Page 1: ...r the person who installs administers and troubleshoots servers and storage systems HP assumes you are qualified in the servicing of computer equipment and trained in recognizing hazards in products with hazardous energy levels Part Number 781889 001 March 2015 Edition 1 ...

Page 2: ...ot be liable for technical or editorial errors or omissions contained herein Linux is the registered trademark of Linus Torvalds in the U S and other countries Microsoft and Windows are U S registered trademarks of the Microsoft group of companies MicroSD is a trademark or a registered trademark of SD 3C in the United States other countries or both Red Hat is a registered trademark of Red Hat Inc ...

Page 3: ...e PCI air baffle 22 Install the PCI air baffle 22 Remove the system air baffle 23 Install the system air baffle 24 Setup 25 Optional installation services 25 Optimum environment 25 Space and airflow requirements 25 Temperature requirements 26 Power requirements 27 Electrical grounding requirements 27 Server warnings and cautions 27 Identifying tower server shipping carton contents 28 Installing ha...

Page 4: ...MMs 65 DIMM identification 65 Memory configurations 66 General DIMM slot population guidelines 67 Installing a DIMM 68 Dedicated iLO management module option 69 Enabling the dedicated iLO management module 71 HP ATX 550 W power supply option 71 Redundant power supply option 74 HP Trusted Platform Module option 80 Installing the Trusted Platform Module board 81 Retaining the recovery key password 8...

Page 5: ...inistrator 107 Automatic Server Recovery 107 USB support 107 Redundant ROM support 108 Keeping the system current 109 Access to HP Support Materials 109 Updating firmware or System ROM 109 Drivers 111 Software and firmware 111 Operating System Version Support 111 Version control 111 HP operating systems and virtualization software support for ProLiant servers 112 HP Technology Service Portfolio 11...

Page 6: ...cations 119 Power supply specifications 120 Hot plug power supply calculations 120 Support and other resources 121 Before you contact HP 121 HP contact information 121 Customer Self Repair 121 Acronyms and abbreviations 129 Documentation feedback 133 Index 134 ...

Page 7: ...Component identification 7 Component identification Front panel components Item Description 1 Optical drive optional 2 Box 2 3 Box 1 4 USB 3 0 connectors ...

Page 8: ... panel flash simultaneously a power fault has occurred For more information see Front panel LED power fault codes on page 8 For the location of the UID button LED on the rear panel see Rear panel LEDs on page 10 Facility power is not present power cord is not attached no power supplies are installed power supply failure has occurred or the power button cable is disconnected If the health LED indic...

Page 9: ...e Front panel LEDs and buttons on page 8 Rear panel components Item Description 1 Non hot plug power supply 2 Power supply bay 1 of the hot plug power supply optional 3 Power supply bay 2 of the hot plug power supply optional 4 NIC connector 1 5 NIC connector 2 6 Dedicated iLO port optional 7 Slot 5 PCIe3x8 8 4 1 8 Slot 4 PCIe3x4 4 1 9 Slot 3 PCIe3x8 8 4 1 10 Slot 2 PCIe3x4 4 1 11 Slot 1 PCIe3x16 ...

Page 10: ...work connection 3 iLO activity LED Green or flashing green Network activity Off No network activity 4 NIC activity LED Green or flashing green Network activity Off No network activity 5 NIC link LED Green Linked to network Off No network connection 6 UID button LED Solid blue Activated Flashing blue 1 Hz cycle per sec Remote management or firmware upgrade in progress 4 Hz cycle per sec iLO manual ...

Page 11: ...5 RPSU connector 6 Processor 7 4 pin power supply connector 8 Front I O connector 9 Fan connector 1 10 Mini SAS connector 1 11 Front USB 3 0 connector 12 SATA connector 2 13 Mini SAS connector 2 14 SATA connector 1 15 Internal USB 3 0 connector 16 Internal USB 2 0 connector 17 Storage backup power connector 18 Hard drive power good cable connector 2 ...

Page 12: ...iguration can be changed On System configuration is locked S3 Off Reserved S4 Off Reserved S5 Off Off Power on password is enabled On Power on password is disabled S6 Off Off No function On ROM reads system configuration as invalid S7 Off Off Set default boot mode to UEFI On Set default boot mode to legacy S8 Reserved S9 Reserved S10 Reserved S11 Reserved S12 Reserved To access the redundant ROM s...

Page 13: ... system and the only available action for administrators is to restart the system Resetting the system erases any information which could support problem analysis but the NMI feature preserves that information by performing a memory dump before a system reset To force the system to invoke the NMI handler and generate a crash dump log do one of the following Use the iLO Virtual NMI feature Short th...

Page 14: ...umbering for each of the supported drive configurations For drive box numbering information see Front panel components on page 7 With optional drive cages installed the server supports up to 4 LFF non hot plug drives 8 LFF hot plug drives or 16 SFF hot plug drives If only one drive cage is installed it must be installed in box 1 The server does not support mixing SFF and LFF drives HP recommends t...

Page 15: ...Component identification 15 Four bay LFF non hot plug drive model Four bay LFF hot plug drive model ...

Page 16: ...art of an array and connected to a powered up controller the drive LEDs indicate the condition of the drive Item LED Status Definition 1 Locate Solid blue The drive is being identified by a host application Flashing blue The drive carrier firmware is being updated or requires an update 2 Activity ring Rotating green Drive activity Off No drive activity 3 Do not remove Solid white Do not remove the...

Page 17: ...d is visible when illuminated IMPORTANT The HP Dynamic Smart Array B140i Controller is only available in UEFI Boot Mode It cannot be enabled in Legacy BIOS Boot Mode If the B140i controller is disabled drives connected to the system board Mini SAS connectors operate in AHCI or Legacy mode Under this condition The drives cannot be a part of a hardware RAID or a logical drive The Locate Drive status...

Page 18: ... the OS before the server enters standby mode Press and hold the Power On Standby button for more than 4 seconds to force the server to enter standby mode This method forces the server to enter standby mode without properly exiting applications and the OS If an application stops responding you can use this method to force a shutdown Use a virtual power button selection through iLO 4 This method in...

Page 19: ... Power down the server on page 18 2 Remove all power a Disconnect each power cord from the power source b Disconnect each power cord from the server 3 Place the server on its side 4 Remove the access panel a Loosen the access panel thumbscrews b Slide and remove the access panel from the server Install the access panel 1 Install the access panel a Place the access panel on the chassis and slide it...

Page 20: ...er 4 Connect each power cord to the power source 5 Power up the server on page 18 Remove the front bezel 1 Power down the server on page 18 2 Remove all power a Disconnect each power cord from the power source b Disconnect each power cord from the server 3 Place the server on its side 4 Remove the access panel on page 18 ...

Page 21: ...o one of the following o Lock the internal locker o Leave the internal locker in unlock position if you want to access the front panel any time without removing the access panel 3 Install the access panel on page 19 4 Return the server to an upright position 5 Connect each power cord to the server 6 Connect each power cord to the power source ...

Page 22: ...ect each power cord from the power source b Disconnect each power cord from the server 3 Place the server on its side 4 Remove the access panel on page 18 5 Remove the PCI air baffle Install the PCI air baffle CAUTION For proper cooling do not operate the server without the access panel baffles expansion slot covers or blanks installed ...

Page 23: ...ect each power cord to the power source 6 Power up the server on page 18 Remove the system air baffle 1 Power down the server on page 18 2 Remove all power a Disconnect each power cord from the power source b Disconnect each power cord from the server 3 Place the server on its side 4 Remove the access panel on page 18 5 If installed remove the PCI air baffle on page 22 ...

Page 24: ... the server without the access panel baffles expansion slot covers or blanks installed 1 Install the system air baffle 2 Install the access panel on page 19 3 Return the server to an upright position 4 Connect each power cord to the server 5 Connect each power cord to the power source 6 Power up the server on page 18 ...

Page 25: ...e Pack services are Hardware support o 6 Hour Call to Repair o 4 Hour 24x7 Same Day o 4 Hour Same Business Day Software support o Microsoft operating systems o Linux operating systems o HP Insight Control o VMware Integrated hardware and software support o Critical Service o Proactive 24 o Support Plus o Support Plus 24 Startup and implementation services for both hardware and software For more in...

Page 26: ...damage The 9000 and 10000 Series Racks provide proper server cooling from flow through perforations in the front and rear doors that provide 64 percent open area for ventilation CAUTION When using a Compaq branded 7000 series rack install the high airflow rack door insert PN 327281 B21 for 42U rack PN 157847 B21 for 22U rack to provide proper front to back airflow and cooling CAUTION If a third pa...

Page 27: ... current rating Do not use common power outlet strips for this equipment Provide a separate electrical circuit for the server For more information on the hot plug power supply and calculators to determine server power consumption in various system configurations see the HP Power Advisor website http www hp com go hppoweradvisor Electrical grounding requirements The server must be grounded properly...

Page 28: ...power cord to remove power from the server The front panel Power On Standby button does not completely shut off system power Portions of the power supply and some internal circuitry remain active until AC power is removed CAUTION Protect the server from power fluctuations and temporary interruptions with a regulating uninterruptible power supply This device protects the hardware from damage caused...

Page 29: ...e walked on or pinched by items placed against it Pay particular attention to the plug electrical outlet and the point where the cord extends from the server Installing the server into a rack To install the server into a rack with square round or threaded holes refer to the instructions that ship with the rack hardware kit If you are installing the server into a telco rack order the appropriate op...

Page 30: ... power supply to disconnect power to the equipment Do not route the power cord where it can be walked on or pinched by items placed against it Pay particular attention to the plug electrical outlet and the point where the cord extends from the server Rack warnings WARNING To reduce the risk of personal injury or damage to the equipment be sure that The leveling jacks are extended to the floor The ...

Page 31: ...ed to update the firmware and systems software Remote deployment installation To deploy an operating system remotely use Insight Control Server Provisioning for an automated solution For additional system software and firmware updates download the HP Service Pack for ProLiant from the HP website http www hp com go spp download Software and firmware must be updated before using the server for the f...

Page 32: ...Setup 32 Registering the server To experience quicker service and more efficient support register the product at the HP Product Registration website http register hp com ...

Page 33: ...to electrical components properly ground the server before beginning any installation procedure Improper grounding can cause electrostatic discharge Drive cage options 4 bay LFF hot plug drive cage option To install the component 1 Power down the server on page 18 2 Remove all power a Disconnect each power cord from the power source b Disconnect each power cord from the server 3 Place the server o...

Page 34: ...n box 1 11 Connect the drive cage cables a Connect one end of the Mini SAS cable to the drive backplane and the other end to the system board b Connect the 8 pin power cable to the drive backplane c Connect the power good cable to the hard drive power good cable connector 1 on the system board System board components on page 11 ...

Page 35: ...cables underneath the metal tabs 12 Install the drives based on the drive numbering on page 14 sequence Start from the drive bay with the lowest number in box 1 13 If installing a 4 bay LFF hot plug drive cage in box 2 remove the drive cage blank ...

Page 36: ...n the server to an upright position 21 Connect each power cord to the server 22 Connect each power cord to the power source 23 Power up the server on page 18 8 bay SFF hot plug drive cage option To install the component 1 Power down the server on page 18 2 Remove all power a Disconnect each power cord from the power source b Disconnect each power cord from the server 3 Place the server on its side...

Page 37: ... 1 11 Connect the drive cage cables a Connect one end of the Mini SAS cable to the drive backplane and the other end to the system board b Connect the 8 pin power cable to the drive backplane c Connect the power good cable to the hard drive power good cable connector 1 on the system board System board components on page 11 ...

Page 38: ...cables underneath the metal tabs 12 Install the drives based on the drive numbering on page 14 sequence Start from the drive bay with the lowest number in box 1 13 If installing a 8 bay SFF hot plug drive cage in box 2 remove the drive cage blank ...

Page 39: ... to the server 23 Connect each power cord to the power source 24 Power up the server on page 18 Drive options For a list of drive configurations supported in this server see Drive numbering on page 14 The embedded storage controller supports SATA drive installation For SAS drive installation install an HP Host Bus Adapter or an HP Smart Array Controller board option For more information about prod...

Page 40: ...s unavailable for data storage Installing a non hot plug drive CAUTION To prevent improper cooling and thermal damage do not operate the server unless all bays are populated with either a component or a blank To install the component 1 Power down the server on page 18 2 Remove all power a Disconnect each power cord from the power source b Disconnect each power cord from the server 3 Place the serv...

Page 41: ...Hardware options installation 41 11 Install the drive into the non hot plug drive cage 12 Install the drive cage into the chassis ...

Page 42: ...17 Install the access panel on page 19 18 Return the server to an upright position 19 Connect each power cord to the server 20 Connect each power cord to the power source 21 Power up the server on page 18 Installing a hot plug drive CAUTION To prevent improper cooling and thermal damage do not operate the server unless all bays are populated with either a component or a blank To install the compon...

Page 43: ...er or an HP Smart Array Controller board option For more information about product features specifications options configurations and compatibility see the product QuickSpecs on the HP website http www hp com go qs Host Bus Adapter Mini SAS cable option To install the component 1 Power down the server on page 18 2 Remove all power a Disconnect each power cord from the power source b Disconnect eac...

Page 44: ...e end of the cable to the Host Bus Adapter route the cable underneath the metal tabs and then connect the other end to the drive backplane o Two 4 LFF hot plug drive cages connected to a H240 adapter Item Description 1 Port 1 controller connection 2 Box 1 drive backplane connection 3 Port 2 controller connection 4 Box 2 drive backplane connection o 8 SFF hot plug drive cage connected to a H240 ada...

Page 45: ...ect each power cord to the power source 16 Power up the server on page 18 Smart Array Controller Mini SAS cable option To install the component 1 Power down the server on page 18 2 Remove all power a Disconnect each power cord from the power source b Disconnect each power cord from the server 3 Place the server on its side 4 Remove the access panel on page 18 5 If installed remove the PCI air baff...

Page 46: ...Port 1 of the Mini SAS Y cable to box 1 drive backplane 3 Port 2 of the Mini SAS Y cable to box 2 drive backplane o Two 4 LFF hot plug drive cages connected to a P840 controller Item Description 1 Port 1 controller connection 2 Port 1 of the Mini SAS Y cable to box 1 drive backplane 3 Port 2 of the Mini SAS Y cable to box 2 drive backplane ...

Page 47: ...n 2 Port 1 of the Mini SAS Y cable to Mini SAS port 1 on the drive backplane 3 Port 2 of the Mini SAS Y cable to Mini SAS port 2 on the drive backplane o 8 SFF hot plug drive cage connected to a P840 controller Item Description 1 Port 1 controller connection 2 Port 1 of the Mini SAS Y cable to Mini SAS port 1 on the drive backplane ...

Page 48: ...orage Battery Pack The DDR cache module buffers and stores data being written by an integrated Gen9 P series Smart Array Controller This server supports the 96 W HP Smart Storage Battery Pack This battery pack can support up to 24 devices Devices in this context refer to the HP Smart Array Controller or NVDIMM associated with the cache module The battery pack might have a low charge when installed...

Page 49: ...HP P series Smart Array Controller or an HP HBA option HP recommends the following guidelines Install this storage controller HBA option In slot Using this cable option H240 adapter Slot 3 or Slot 5 HP Host Bus Adapter Mini SAS cable option P440 controller Slot 3 or Slot 5 HP Smart Array Controller Mini SAS cable option P840 controller Slot 3 or Slot 5 HP Smart Array Controller Mini SAS cable opti...

Page 50: ...Hardware options installation 50 a If you are installing an HP Smart Array P440 Controller remove the air scoop b Connect the cache module backup power cable to the module ...

Page 51: ...ule on the storage controller d If you are installing an HP Smart Array P440 Controller install the air scoop back onto the controller 8 Locate the appropriate PCIe slot to install the storage controller Storage controller installation guidelines on page 49 ...

Page 52: ...rmation see FBWC module cabling on page 91 12 Connect all necessary cables to the storage controller and drive cage backplane For internal drive cabling information see Storage cabling on page 84 13 Install the system air baffle on page 24 14 If removed install the PCI air baffle Install the PCI air baffle on page 22 15 Install the access panel on page 19 16 Return the server to an upright positio...

Page 53: ...age Battery holder if not installed HP Smart Storage Battery holder option on page 53 8 Install the HP Smart Storage Battery and then connect the battery cable to the system board connector 9 Install the system air baffle on page 24 10 If removed install the PCI air baffle Install the PCI air baffle on page 22 11 Install the access panel on page 19 12 Return the server to an upright position 13 Co...

Page 54: ...el on page 18 5 If installed remove the PCI air baffle on page 22 6 Remove the system air baffle on page 23 7 Remove the slot covers 8 Install the HP Smart Storage Battery holders 9 Install the system air baffle on page 24 10 If removed install the PCI air baffle Install the PCI air baffle on page 22 11 Install the access panel on page 19 12 Return the server to an upright position ...

Page 55: ... option is only required if you install the K4200 GPU card To install the component 1 Power down the server on page 18 2 Remove all power a Disconnect each power cord from the power source b Disconnect each power cord from the server 3 Place the server on its side 4 Remove the access panel on page 18 5 If installed remove the PCI air baffle on page 22 6 Remove the system air baffle on page 23 7 Re...

Page 56: ...cover retainer and remove the slot 1 blank 10 Retain the blank for future use 11 Remove the secured screw from the system board 12 Install the GPU with the supporting holder in slot 1 a Secure the captive screw of the supporting holder to the system board ...

Page 57: ... GPU 14 Install the system air baffle on page 24 15 If removed install the PCI air baffle Install the PCI air baffle on page 22 16 Install the access panel on page 19 17 Return the server to an upright position 18 Connect each power cord to the server 19 Connect each power cord to the power source 20 Power up the server on page 18 ...

Page 58: ...wer a Disconnect each power cord from the power source b Disconnect each power cord from the server 3 Place the server on its side 4 Remove the access panel on page 18 5 Remove the front bezel on page 20 6 If installed remove the PCI air baffle on page 22 7 Remove the system air baffle on page 23 8 Remove the optical drive cover ...

Page 59: ...Hardware options installation 59 9 Remove the EMI shield from the front panel 10 Connect the cable to the rear of the drive and then route the cable through the drive bay 11 Connect the power cable ...

Page 60: ... 20 Power up the server on page 18 PCI fan and baffle option CAUTION For proper cooling do not operate the server without the access panel baffles expansion slot covers or blanks installed If you intend to install a storage controller GPU card or any expansion boards in the PCIe slot area except the dedicated iLO module a PCI fan and baffle option is required to provide proper cooling of the PCIe ...

Page 61: ... the server on page 18 System fan upgrade option For more information about product features specifications options configurations and compatibility see the product QuickSpecs on the HP website http www hp com go qs To install the component 1 Power down the server on page 18 2 Remove all power a Disconnect each power cord from the power source b Disconnect each power cord from the server 3 Place t...

Page 62: ...l the system air baffle on page 24 10 If removed install the PCI air baffle Install the PCI air baffle on page 22 11 Install the access panel on page 19 12 Return the server to an upright position 13 Connect each power cord to the server 14 Connect each power cord to the power source 15 Power up the server on page 18 ...

Page 63: ...P Smart Storage Battery 8 Install the device adapter on the system board 9 Install the HP Smart Storage Battery on the server 10 Install the system air baffle on page 24 11 If removed install the PCI air baffle Install the PCI air baffle on page 22 12 Install the access panel on page 19 13 Return the server to an upright position 14 Connect each power cord to the server 15 Connect each power cord ...

Page 64: ...33 RDIMM Dual rank 8 GB 2133 RDIMM Dual rank 16 GB 2133 LRDIMM Dual rank 16 GB 2133 RDIMM Dual rank 32 GB 2133 Populated DIMM speed MT s DIMM type DIMM rank 1 DIMM per channel 2 DIMMs per channel RDIMM Single rank 2133 2133 RDIMM Dual rank 2133 2133 For more information about product features specifications options configurations and compatibility see the product QuickSpecs on the HP website http ...

Page 65: ...o single rank DIMMs on the same module with only one rank accessible at a time A quad rank DIMM is effectively two dual rank DIMMs on the same module Only one rank is accessible at a time The server memory control subsystem selects the proper rank within the DIMM when writing to or reading from the DIMM Dual and quad rank DIMMs provide the greatest capacity with the existing memory technology For ...

Page 66: ...Ms Certain memory is reserved as spare and automatic failover to spare memory occurs when the system detects a DIMM that is degrading This allows DIMMs that have a higher probability of receiving an uncorrectable memory error which would result in system downtime to be removed from operation Advanced Memory Protection options are configured in the BIOS Platform Configuration RBSU If the requested ...

Page 67: ...ranks are available for OS and application use If correctable memory errors occur at a rate higher than a specific threshold on any of the non spare ranks the server automatically copies the memory contents of the degraded rank to the online spare rank The server then deactivates the failing rank and automatically switches over to the online spare rank General DIMM slot population guidelines Obser...

Page 68: ...hannel must have a spare rank A single dual rank DIMM is not a valid configuration Population order For memory configurations with a single processor or multiple processors DIMMs must be populated sequentially in alphabetical order A through H After installing the DIMMs use the BIOS Platform Configuration RBSU in the UEFI System Utilities to configure supported AMP modes Installing a DIMM 1 Power ...

Page 69: ...er cord to the server 14 Connect each power cord to the power source 15 Power up the server on page 18 Dedicated iLO management module option To install the component 1 Power down the server on page 18 2 Remove all power a Disconnect each power cord from the power source b Disconnect each power cord from the server 3 Place the server on its side 4 Remove the access panel on page 18 5 If installed ...

Page 70: ...close the slot cover 9 Install the system air baffle on page 24 10 If removed install the PCI air baffle Install the PCI air baffle on page 22 11 Install the access panel on page 19 12 Return the server to an upright position 13 Connect each power cord to the server 14 Connect each power cord to the power source 15 Power up the server on page 18 ...

Page 71: ... for later reference HP ATX 550 W power supply option This section provides instructions for installing a HP ATX 550 W power supply option in HP ProLiant ML110 Gen9 Server WARNING To reduce the risk of personal injury from hot surfaces allow the drives and the internal system components to cool before touching them CAUTION To prevent damage to electrical components take the appropriate anti static...

Page 72: ... the 550 W ATX power cables and then route the cables underneath the metal tabs o 4 LFF non hot plug configuration Optical drive power cable to optical drive 8 pin drive power cable to the non hot plug drive power connector 6 pin power cable connecting to GPU if installed 4 pin power cable connecting to system board ...

Page 73: ...SFF hot plug configuration Optical drive power cable to optical drive 8 pin drive power cable to the hot plug drive backplanes 6 pin power cable connecting to GPU if installed 4 pin power cable connecting to system board 24 pin power cable connecting to system board 4 LFF hot plug configuration ...

Page 74: ... the installation of one power input module and power redundancy requires the installation of two power input modules This module is a separately purchased option and is not part of the RPS enablement option kit When this RPS backplane enablement option and a single power input module are installed in the server you can install or remove a second power input module without powering down the server...

Page 75: ...rmal damage do not operate the server unless all bays are populated with either a component or a blank For more information about product features specifications options configurations and compatibility see the product QuickSpecs on the HP website http www hp com go qs To install the component 1 Power down the server on page 18 2 Remove all power a Disconnect each power cord from the power source ...

Page 76: ...y cables from the RPS backplane assembly and then insert the backplane into the bay carefully 11 Connect the RPS backplane cables and then route the cables underneath the metal tabs o 4 LFF non hot plug configuration Optical drive power cable to optical drive 8 pin drive power cable to the non hot plug drive power connector 4 pin power cable to system board 6 pin power cable to GPU if installed RP...

Page 77: ... hot plug configuration Optical drive power cable to optical drive 8 pin drive power cable to the hot plug drive backplanes 4 pin power cable to system board 6 pin power cable to GPU if installed RPSU cable to system board 24 pin power cable to system board 4 LFF hot plug configuration ...

Page 78: ...put module in the power supply bay 1 NOTE When facing the rear of the server in an upright position the upper level of power supply bay is bay 1 and the lower level is bay 2 13 If you intend to enable power redundancy in the server install a second power input module in the power supply bay 2 ...

Page 79: ...cooling and thermal damage do not operate the server unless all bays are populated with either a component or a blank 14 Install the system air baffle on page 24 15 If removed install the PCI air baffle Install the PCI air baffle on page 22 16 Install the access panel on page 19 17 Connect the power cords to the power supplies 18 Connect the power cords to the AC power source ...

Page 80: ...ormation about product features specifications options configurations and compatibility see the product QuickSpecs on the HP website http www hp com go qs Use these instructions to install and enable a TPM on a supported server This procedure includes three sections 1 Installing the Trusted Platform Module board 2 Retaining the recovery key password on page 83 3 Enabling the Trusted Platform Modul...

Page 81: ...talled TPM administrators should consider the system compromised and take appropriate measures to ensure the integrity of the system data When using BitLocker always retain the recovery key password The recovery key password is required to enter Recovery Mode after BitLocker detects a possible compromise of system integrity HP is not liable for blocked data access caused by improper TPM use For op...

Page 82: ... firmly into the system board 10 Install the controller in slot 5 11 Install the system air baffle on page 24 12 If removed install the PCI air baffle Install the PCI air baffle on page 22 13 Install the access panel on page 19 14 Return the server to an upright position 15 Connect each power cord to the server 16 Connect each power cord to the power source 17 Power up the server on page 18 ...

Page 83: ...m Module Options and press the Enter key 4 Select Enabled to enable the TPM and BIOS secure startup The TPM is fully functional in this mode 5 Press the F10 key to save your selection 6 When prompted to save the change in System Utilities press the Y key 7 Press the ESC key to exit System Utilities Then press the Enter key when prompted to reboot the server The server then reboots a second time wi...

Page 84: ...abling peripheral components refer to the white paper on high density deployment at the HP website http www hp com products servers platforms CAUTION When routing cables always be sure that the cables are not in a position where they can be pinched or crimped Storage cabling 4 bay LFF non hot plug drive cabling Box 1 Item Description 1 Power supply cable 2 Box 1 drive power cable 3 Mini SAS cable ...

Page 85: ... backplane connected to the system board Item Description 1 Drive power cable 2 Mini SAS cable 3 Hard drive power good cable Box 2 drive backplane connected the system board Item Description 1 Drive power cable 2 Mini SAS cable 3 Hard drive power good cable ...

Page 86: ...cable 3 Mini SAS cable to port 2 of the controller 4 Mini SAS cable to port 1of the controller 5 Box 1 hard drive power good cable 6 Box 2 hard drive power good cable Box 1 and box 2 drive backplanes connected to a P440 controller Item Description 1 Box 2 drive power cable 2 Box 1 drive power cable 3 Mini SAS Y cable to the controller ...

Page 87: ...rd drive power good cable Box 1 and box 2 drive backplane connected to a P840 controller Item Description 1 Box 2 drive power cable 2 Box 1 drive power cable 3 Mini SAS Y cable to port 1 of the controller 4 Box 2 hard drive power good cable 5 Box 1 hard drive power good cable ...

Page 88: ...scription 1 Drive power cable 2 Mini SAS port 1 connection 3 Mini SAS port 2 connection 4 Hard drive power good cable Box 1 drive backplane connected to an H240 adapter Item Description 1 Drive power cable 2 Mini SAS port 1 connection to port 1 controller 3 Mini SAS port 2 connection to port 2 controller ...

Page 89: ...40 adapter Item Description 1 Drive power cable 2 Mini SAS port 1 connection to port 1 controller 3 Mini SAS port 2 connection to port 2 controller 4 Hard drive power good cable Box 1 drive backplane connected to a P440 controller Item Description 1 Drive power cable 2 Mini SAS Y cable to controller ...

Page 90: ...to a P440 controller Item Description 1 Drive power cable 2 Mini SAS Y cable to controller 3 Hard drive power good cable Box 1 drive backplane connected to a P840 controller Item Description 1 Drive power cable 2 Mini SAS Y cable connection to port 1 controller 3 Hard drive power good cable ...

Page 91: ...ower good cable FBWC module cabling The FBWC solution is a separately purchased option This server only supports FBWC module installation when an HP Smart Array P Series controller is installed Depending on the controller option installed the actual storage controller connectors might look different from what is shown in this section FBWC module on a P440 controller ...

Page 92: ...Cabling 92 FBWC module on a P840 controller HP Smart Storage Battery cabling ...

Page 93: ...Cabling 93 Optical drive cabling Item Description 1 Power supply cable 2 Drive power cable 3 SATA cable Fan cabling Default system fan 92 x 32 mm ...

Page 94: ...Cabling 94 Optional system upgrade fan 92 x 38 mm PCI fan ...

Page 95: ...ly non hot plug Item Description 1 8 pin power supply cable to box 2 drive backplane and optical drive 2 8 pin power supply cable to box 1 drive backplane 3 4 pin power cable to system board 4 24 pin power supply cable HP ATX 550 W power supply non hot plug ...

Page 96: ...ane 4 4 pin power cable to system board 5 24 pin power cable to system board HP 750 W redundant power supply Item Description 1 8 pin power supply cable to box 2 drive backplane and optical drive 2 8 pin power supply cable to box 1 drive backplane 3 6 pin power cable to GPU 4 4 pin power cable to system board 5 RPS cable to system board 6 24 pin power cable to system board ...

Page 97: ...Cabling 97 Front I O cabling Front USB 3 0 cabling ...

Page 98: ...trator on page 107 Online and Offline FWUPDATE utility on page 109 Offline Product QuickSpecs For more information about product features specifications options configurations and compatibility see the product QuickSpecs on the HP website http www hp com go qs HP iLO The iLO 4 subsystem is a standard component of HP ProLiant servers that simplifies initial server setup server health monitoring pow...

Page 99: ...ement tool For more information about iLO 4 features see the iLO 4 documentation on the HP website http www hp com go ilo docs The HP iLO 4 hardware and firmware features and functionality such as NAND size and embedded user partition vary depending on the server model For a complete list of supported features and functionality see the HP iLO 4 QuickSpecs on the HP website http h18000 www1 hp com ...

Page 100: ...ide on the HP website http www hp com go ilo docs HP Intelligent Provisioning User Guide on the HP website http www hp com go intelligentprovisioning docs HP RESTful API support for HP iLO HP iLO 4 firmware version 2 00 and later includes the HP RESTful API The HP RESTful API is a management interface that server management tools can use to perform configuration inventory and monitoring of an HP P...

Page 101: ...nline For more information see HP Insight Remote Support Release Notes on the HP website http www hp com go insightremotesupport docs HP Insight Online direct connect When you use the embedded Remote Support functionality with HP ProLiant Gen8 and later server models and HP BladeSystem c Class enclosures you can register a server or chassis to communicate directly to HP Insight Online without the ...

Page 102: ...tics Online Edition is a web based application that captures system configuration and other related data needed for effective server management Available in Microsoft Windows and Linux versions the utility helps to ensure proper system operation For more information or to download the utility see the HP website http www hp com servers diags HP Insight Diagnostics Online Edition is also available i...

Page 103: ...pting Toolkit see the HP website http www hp com go ProLiant STK HP Service Pack for ProLiant SPP is a comprehensive systems software drivers and firmware solution delivered as a single package with major server releases This solution uses HP SUM as the deployment tool and is tested on all supported HP ProLiant servers including HP ProLiant Gen8 and later servers SPP can be used in an online mode ...

Page 104: ...ell For on screen help press F1 Using HP UEFI System Utilities To use the System Utilities use the following keys Action Key Access System Utilities F9 during server POST Navigate menus Up and Down arrows Select items Enter Save selections F10 Access Help for a highlighted configuration option F1 Scan the QR code on the screen to access online help for the UEFI System Utilities and UEFI Shell Defa...

Page 105: ...cessary and then save the configuration as the custom default configuration When the system loads the default settings it uses the custom default settings instead of the factory defaults Secure Boot configuration Secure Boot is integrated in the UEFI specification on which the HP implementation of UEFI is based Secure Boot is completely implemented in the BIOS and does not require special hardware...

Page 106: ...ort configuring the UEFI BIOS settings using the HP RESTful API a management interface that server management tools can use to perform configuration inventory and monitoring of an HP ProLiant server A REST client uses HTTPS operations to configure supported server settings such as UEFI BIOS settings For more information about the HP RESTful API and the HP RESTful Interface Tool see the HP website ...

Page 107: ...resets the timer However when the operating system fails the timer expires and restarts the server ASR increases server availability by restarting the server within a specified time after a system hang You can disable ASR from the System Management Homepage or through UEFI System Utilities USB support HP servers support both USB 2 0 ports and USB 3 0 ports Both types of ports support installing al...

Page 108: ...ebsite http www hp com go ProLiantUEFI docs External USB functionality HP provides external USB support to enable local connection of USB devices for server administration configuration and diagnostic procedures For additional security external USB functionality can be disabled through USB options in UEFI System Utilities Internal USB functionality An internal USB connector is available for use wi...

Page 109: ...09 FWUPDATE utility The FWUPDATE utility enables you to upgrade the system firmware BIOS To use the utility to upgrade the firmware 1 Download the FWUPDATE flash component from the HP website http www hp com go hpsc 2 Save the FWUPDATE flash components to a USB key 3 Set the boot order so the USB key will boot first using one of the following options o Configure the boot order so the USB key is th...

Page 110: ...ates to take effect and for hardware stability to be maintained For more information about the commands used in this procedure see the HP UEFI Shell User Guide for HP ProLiant Gen9 Servers on the HP website http www hp com go ProLiantUEFI docs Firmware Update application in System Utilities For systems configured in either boot mode update the firmware 1 Access the System ROM Flash Binary componen...

Page 111: ...ers Software Firmware Then enter your product name in the Find an HP product field and click Go Software and firmware Software and firmware should be updated before using the server for the first time unless any installed software or components require an older version For system software and firmware updates use one of the following sources Download the SPP HP Service Pack for ProLiant on page 10...

Page 112: ...d cloud computing big data and mobility requirements improving data center infrastructure and better use of today s server storage and networking technology For more information see the HP website http www hp com services consulting Our support portfolio covers services for HP server storage and networking hardware and software plus the leading industry standard operating systems Let us work proac...

Page 113: ...ort Gen9_TSG_es German http www hp com support Gen9_TSG_de Japanese http www hp com support Gen9_TSG_ja Simplified Chinese http www hp com support Gen9_TSG_zh_cn The HP ProLiant Gen9 Troubleshooting Guide Volume II Error Messages provides a list of error messages and information to assist with interpreting and resolving error messages on ProLiant servers and server blades To view the guide select ...

Page 114: ...the battery Do not expose the battery to temperatures higher than 60 C 140 F Do not disassemble crush puncture short external contacts or dispose of in fire or water Replace only with the spare designated for this product To remove the component 1 Power down the server on page 18 2 Remove all power a Disconnect each power cord from the power source b Disconnect each power cord from the server 3 Pl...

Page 115: ...system ROM to its default configuration After replacing the battery reconfigure the system through RBSU To replace the component reverse the removal procedure For more information about battery replacement or proper disposal contact an authorized reseller or an authorized service provider ...

Page 116: ... HP website http www hp com support Safety Compliance EnterpriseProducts Belarus Kazakhstan Russia marking Manufacturer Hewlett Packard Company Address 3000 Hanover Street Palo Alto California 94304 U S Local representative information Russian HP Russia HP Belarus HP Kazakhstan Local representative information Kazakh Manufacturing date The manufacturing date is defined by the serial number HP seri...

Page 117: ...tent declaration Ukraine RoHS material content declaration Warranty information HP ProLiant and X86 Servers and Options http www hp com support ProLiantServers Warranties HP Enterprise Servers http www hp com support EnterpriseServers Warranties HP Storage Products http www hp com support Storage Warranties HP Networking Products http www hp com support Networking Warranties GS Gloss declaration T...

Page 118: ...atic sensitive component or assembly Grounding methods to prevent electrostatic discharge Several methods are used for grounding Use one or more of the following methods when handling or installing electrostatic sensitive parts Use a wrist strap connected by a ground cord to a grounded workstation or computer chassis Wrist straps are flexible straps with a minimum of 1 megohm 10 percent resistance...

Page 119: ...change might be limited by the type and number of options installed For certain approved hardware configurations the supported system inlet temperature range is extended 5 C to 10 C 41 F to 50 F and 35 C to 40 C 95 F to 104 F at sea level with an altitude derating of 1 0 C per every 175 m 1 8 F per every 574 ft above 900 m 2953 ft to a maximum of 3048 m 10 000 ft 40 C to 45 C 104 F to 113 F at sea...

Page 120: ...t Plug Power Supply 512327 B21 This is supported when the two bay HP RPS Enablement option PN 784582 B21 is installed These are Entry Level Power Supply products for HP ProLiant servers For more information about the power supply features specifications and compatibility see the HP website http www hp com go proliant powersupply CAUTION Check the system and power supply input ratings before poweri...

Page 121: ...cation number Applicable error messages Add on boards or hardware Third party hardware or software Operating system type and revision level HP contact information For United States and worldwide contact information see the Contact HP website http www hp com go assistance In the United States To contact HP by phone call 1 800 334 5144 For continuous quality improvement calls may be recorded or moni...

Page 122: ... selfrepair Réparation par le client CSR Les produits HP comportent de nombreuses pièces CSR Customer Self Repair réparation par le client afin de minimiser les délais de réparation et faciliter le remplacement des pièces défectueuses Si pendant la période de diagnostic HP ou ses partenaires ou mainteneurs agréés détermine que la réparation peut être effectuée à l aide d une pièce CSR HP vous l en...

Page 123: ...mento di costo solo in alcune zone In caso di necessità si può richiedere l assistenza telefonica di un addetto del centro di supporto tecnico HP Nel materiale fornito con una parte di ricambio CSR HP specifica se il cliente deve restituire dei componenti Qualora sia richiesta la resa ad HP del componente difettoso lo si deve spedire ad HP entro un determinato periodo di tempo generalmente cinque ...

Page 124: ...o socios de servicio de HP identifica que una reparación puede llevarse a cabo mediante el uso de un componente CSR HP le enviará dicho componente directamente para que realice su sustitución Los componentes CSR se clasifican en dos categorías Obligatorio componentes para los que la reparación por parte del usuario es obligatoria Si solicita a HP que realice la sustitución de estos componentes ten...

Page 125: ...en in de geïllustreerde onderdelencatalogus aangemerkt met Nee Afhankelijk van de leverbaarheid en de locatie worden CSR onderdelen verzonden voor levering op de eerstvolgende werkdag Levering op dezelfde dag of binnen vier uur kan tegen meerkosten worden aangeboden indien dit mogelijk is gezien de locatie Indien assistentie gewenst is belt u een HP Service Partner om via de telefoon technische on...

Page 126: ... horas pode ser feita mediante uma taxa adicional Se precisar de auxílio entre em contato com o Centro de suporte técnico da HP para que um técnico o ajude por telefone A HP especifica nos materiais fornecidos com a peça CSR de reposição se a peça com defeito deve ser devolvida à HP Nos casos em que isso for necessário é preciso enviar a peça com defeito à HP dentro do período determinado normalme...

Page 127: ...Support and other resources 127 ...

Page 128: ...Support and other resources 128 ...

Page 129: ...nced Memory Protection ASHRAE American Society of Heating Refrigerating and Air Conditioning Engineers ASR Automatic Server Recovery CSA Canadian Standards Association CSR Customer Self Repair DDR double data rate FAT file allocation table FBWC flash backed write cache GPU graphics processing unit HBA host bus adapter ...

Page 130: ...trotechnical Commission iLO Integrated Lights Out IML Integrated Management Log ISO International Organization for Standardization JSON JavaScript Object Notation LFF large form factor LRDIMM load reduced dual in line memory module NMI nonmaskable interrupt NVRAM nonvolatile memory PCIe Peripheral Component Interconnect Express PDU power distribution unit ...

Page 131: ...oHS Restriction of Hazardous Substances RPS redundant power supply SAS serial attached SCSI SATA serial ATA SFF small form factor SIM Systems Insight Manager SPP HP Service Pack for ProLiant SSD solid state drive TMRA recommended ambient operating temperature TPM Trusted Platform Module UEFI Unified Extensible Firmware Interface ...

Page 132: ...Acronyms and abbreviations 132 UID unit identification USB universal serial bus VC Virtual Connect VCA Version Control Agent VCRM Version Control Repository Manager ...

Page 133: ...oviding documentation that meets your needs To help us improve the documentation send any errors suggestions or comments to Documentation Feedback mailto docsfeedback hp com Include the document title and part number version number or the URL when submitting your feedback ...

Page 134: ...95 cabling optical drive 93 cabling redundant power supply 96 cache module battery pack 53 cache module installation 49 Care Pack 25 101 112 121 cautions 27 30 118 central connect 101 Change Control 104 107 112 change control and proactive notification 112 clearing NVRAM 12 CMOS 12 components front panel 7 components identification 7 components rear panel 9 components system board 11 configuration...

Page 135: ...stall 55 grounding methods 118 grounding requirements 27 118 GS gloss declaration 116 117 H hardware options 33 hardware options installation 29 33 health driver 107 health LED 8 help resources 121 hot plug power supply 74 hot plug power supply calculations 120 HP Care Pack Services 25 112 HP Collaborative Support 112 HP contact information 121 HP iLO 98 HP Insight Diagnostics 102 HP Insight Diagn...

Page 136: ...unctionality 13 NMI header 13 non hot plug drives installing 40 non hot plug power supply 120 notification actions 112 O online flash components 109 110 online spare memory 67 68 online spare population guidelines 67 68 operating environment recommended 25 operating system crash 13 107 operating system installation 31 112 operating system version support 111 112 operating systems 111 112 operating...

Page 137: ...ns 27 Service Packs 103 setup 25 shipping carton contents 28 site requirements 25 Smart Update Firmware DVD 101 Smart Update Manager 98 103 software 111 112 software upgrades 111 space and airflow requirements 25 space requirements 25 specifications environmental 119 specifications power supply 120 specifications server 119 SPP 102 103 static electricity 118 storage cabling hot plug 85 88 storage ...

Page 138: ...ly 27 USB universal serial bus 63 107 USB connector 7 USB support 107 utilities 98 104 107 utilities deployment 98 103 V VCA Version Control Agent 111 VCRM Version Control Repository Manager 111 ventilation 25 Version Control Agent VCA 111 Version Control Repository Manager VCRM 111 Virtualization option 112 W warnings 27 30 warranty information 117 website HP 121 ...

Reviews: