Hardware options installation 45
Item
Description
1
Port 1 controller connection
2
Mini-SAS port 1 connection
3
Port 2 controller connection
4
Mini-SAS port 2 connection
9.
Install the Host Bus Adapter. HP recommends installing the H240 Host Bus Adapter in slot 3 or slot 5.
10.
Install the system air baffle (on page
24
).
11.
If removed, install the PCI air baffle ("
Install the PCI air baffle
" on page
22
).
12.
Install the access panel (on page
19
).
13.
Return the server to an upright position.
14.
Connect each power cord to the server.
15.
Connect each power cord to the power source.
16.
Power up the server (on page
18
).
Smart Array Controller Mini-SAS cable option
To install the component:
1.
Power down the server (on page
18
).
2.
Remove all power:
a.
Disconnect each power cord from the power source.
b.
Disconnect each power cord from the server.
3.
Place the server on its side.
4.
Remove the access panel (on page
18
).
5.
If installed, remove the PCI air baffle (on page
22
).
6.
Remove the system air baffle (on page
23
).
7.
Disconnect the existing Mini-SAS cables from the drive backplane and the Mini-SAS connectors on the
system board.
8.
Connect one end of the cable to the Smart Array Controller, route the cable underneath the metal tabs,
and then connect the other end to the drive backplane.
Summary of Contents for ProLiant ML110 Gen9
Page 92: ...Cabling 92 FBWC module on a P840 controller HP Smart Storage Battery cabling ...
Page 94: ...Cabling 94 Optional system upgrade fan 92 x 38 mm PCI fan ...
Page 97: ...Cabling 97 Front I O cabling Front USB 3 0 cabling ...
Page 127: ...Support and other resources 127 ...