Software and configuration utilities 110
FWUpdate command from within the Embedded UEFI Shell
For systems configured in either boot mode, update the firmware:
1.
Access the System ROM Flash Binary component for your server from the HP Support Center
(
http://www.hp.com/go/hpsc
). When searching for the component, always select
OS Independent
to
locate the binary file.
2.
Copy the binary file to a USB media or iLO virtual media.
3.
Attach the media to the server.
4.
Boot to Embedded Shell.
5.
To obtain the assigned file system volume for the USB key, enter
Map –r
. For more information about
accessing a file system from the shell, see the
HP UEFI Shell User Guide for HP ProLiant Gen9 Servers
on the HP website (
http://www.hp.com/go/ProLiantUEFI/docs
).
6.
Change to the file system that contains the System ROM Flash Binary component for your server. Enter
one of the fsx file systems available, such as
fs0
or
fs1
, and press
Enter
.
7.
Use the
cd
command to change from the current directory to the directory that contains the binary file.
8.
Enter
fwupdate –d BIOS -f <filename>
to flash the system ROM.
For help on the FWUPDATE command, enter the command:
help fwupdate -b
9.
Reboot the server. A reboot is required after the firmware update for the updates to take effect and for
hardware stability to be maintained.
For more information about the commands used in this procedure, see the
HP UEFI Shell User Guide for HP
ProLiant Gen9 Servers
on the HP website (
http://www.hp.com/go/ProLiantUEFI/docs
).
Firmware Update application in System Utilities
For systems configured in either boot mode, update the firmware:
1.
Access the System ROM Flash Binary component for your server from the HP Support Center
(
http://www.hp.com/go/hpsc
). When searching for the component, always select
OS Independent
to
find the component.
2.
Copy the binary file to a USB media or iLO virtual media.
3.
Attach the media to the server.
4.
During POST, press
F9
to enter System Utilities.
5.
Select
Embedded Applications
→
Firmware Update
→
System ROM
→
Select Firmware File
.
6.
Select the device containing the flash file.
7.
Select the flash file. This step may take a few moments to complete.
8.
Select
Start firmware update
and allow the process to complete.
9.
Reboot the server. A reboot is required after the firmware update for the updates to take effect and for
hardware stability to be maintained.
Online Flash components
This component provides updated system firmware that can be installed directly on supported Operating
Systems. Additionally, when used in conjunction with HP SUM ("
HP Smart Update Manager
" on page
103
),
this Smart Component allows the user to update firmware on remote servers from a central location. This
Summary of Contents for ProLiant ML110 Gen9
Page 92: ...Cabling 92 FBWC module on a P840 controller HP Smart Storage Battery cabling ...
Page 94: ...Cabling 94 Optional system upgrade fan 92 x 38 mm PCI fan ...
Page 97: ...Cabling 97 Front I O cabling Front USB 3 0 cabling ...
Page 127: ...Support and other resources 127 ...
Page 128: ...Support and other resources 128 ...