![HP ProLiant ML110 Gen9 User Manual Download Page 68](http://html.mh-extra.com/html/hp/proliant-ml110-gen9/proliant-ml110-gen9_user-manual_164839068.webp)
Hardware options installation 68
Advanced ECC population guidelines
For Advanced ECC mode configurations, observe the following guidelines:
•
Observe the general DIMM slot population guidelines.
•
DIMMs may be installed individually.
Online spare population guidelines
For Online Spare memory mode configurations, observe the following guidelines:
•
Observe the general DIMM slot population guidelines.
•
Each channel must have a valid online spare configuration.
•
Each channel can have a different valid online spare configuration.
•
Each populated channel must have a spare rank. A single dual-rank DIMM is not a valid configuration.
Population order
For memory configurations with a single processor or multiple processors, DIMMs must be populated
sequentially in alphabetical order (A through H).
After installing the DIMMs, use the BIOS/Platform Configuration (RBSU) in the UEFI System Utilities to
configure supported AMP modes.
Installing a DIMM
1.
Power down the server (on page
18
).
2.
Remove all power:
a.
Disconnect each power cord from the power source.
b.
Disconnect each power cord from the server.
3.
Place the server on its side.
4.
Remove the access panel (on page
18
).
5.
If installed, remove the PCI air baffle (on page
22
).
6.
Remove the system air baffle (on page
23
).
7.
Open the DIMM slot latches.
Summary of Contents for ProLiant ML110 Gen9
Page 92: ...Cabling 92 FBWC module on a P840 controller HP Smart Storage Battery cabling ...
Page 94: ...Cabling 94 Optional system upgrade fan 92 x 38 mm PCI fan ...
Page 97: ...Cabling 97 Front I O cabling Front USB 3 0 cabling ...
Page 127: ...Support and other resources 127 ...