Hardware options installation 92
•
Always install DIMMs in channels 1 and 2 for each installed processor.
•
Do not install DIMMs in channel 3 for any processor.
•
DIMMs installed on channel 1 and channel 2 of an installed processor must be identical.
•
In multi-processor configurations, each processor must have a valid Mirrored Memory configuration.
•
In multi-processor configurations, each processor may have a different valid Mirrored Memory
configuration.
Installing a DIMM
1.
Power down the server (on page
20
).
2.
Remove all power:
a.
Disconnect each power cord from the power source.
b.
Disconnect each power cord from the server.
3.
Do one of the following:
o
Extend the server from the rack (on page
20
).
o
Remove the server from the rack (on page
22
).
4.
Remove the access panel (on page
24
).
5.
Remove the air baffle (on page
29
).
6.
Open the DIMM slot latches.
7.
Install the DIMM.
8.
Install the air baffle (on page
30
).
9.
Install the access panel (on page
26
).
10.
Do one of the following:
o
Slide the server into the rack.
o
Install the server into the rack ("
Installing the server into the rack
" on page
36
).
11.
Power up the server (on page
20
).
After installing the DIMMs, use BIOS/Platform Configuration (RBSU) in the UEFI System Utilities ("
HP UEFI
System Utilities
" on page
133
) to configure the memory protection mode.