![HP ProLiant DL180 Gen9 User Manual Download Page 71](http://html.mh-extra.com/html/hp/proliant-dl180-gen9/proliant-dl180-gen9_user-manual_164669071.webp)
Hardware options installation 71
10.
If you installed a cache module on the storage controller, connect the cache module backup power
cable to the riser board.
11.
Connect the other end of the storage controller cables to the drive backplane. For internal drive cabling
information, see "Storage cabling (on page
113
)."
12.
If you are planning to install an HP Smart Storage Battery Pack, install it now ("
Installing an HP Smart
Storage Battery
" on page
71
).
13.
Install the access panel (on page
26
).
14.
Do one of the following:
o
Slide the server into the rack.
o
Install the server into the rack ("
Installing the server into the rack
" on page
36
).
15.
Power up the server (on page
20
).
16.
If you are planning to install new drives, install them now ("
Drive options
" on page
43
).
For more information about the integrated storage controller and its features, select the relevant user
documentation on the HP website (
http://www.hp.com/go/smartstorage/docs
).
To configure arrays, see the
HP Smart Storage Administrator User Guide
on the HP website
(
http://www.hp.com/go/smartstorage/docs
).
Installing an HP Smart Storage Battery
For more information about product features, specifications, options, configurations, and compatibility, see
the product QuickSpecs on the HP website (
http://www.hp.com/go/qs
).
CAUTION:
In systems that use external data storage, be sure that the server is the first unit to be
powered down and the last to be powered back up. Taking this precaution ensures that the system
does not erroneously mark the external drives as failed when the server is powered up.
To install the component:
1.
Power down the server (on page
20
).
2.
Remove all power: