Physical and Operating Specifications
5-4
HP ProLiant DL145 Generation 2 Server Maintenance and Service Guide
Table 5-2: Physical Dimensions
Item Description
System board platform
EATX (Extended Advanced Technology eXtended)
System board dimensions
Length
Width
295 mm (11.6 in.)
412 mm (16.2 in.)
Server dimensions
Height
Width
Depth
43.2 mm (1.7 in)
426.36 mm (16.79 in)
679.5 mm (26.75 in)
Server weight (maximum
configuration)
15.87 kg (35 lb)
Table 5-3: Environmental Specifications
Item Description
Temperature
Operating
Non-operating (unpacked)
Storage (unpacked)
Shipping (packed)
10
°
to 35°C (50
°
to 95°F)
0
°
to 50°C (32
°
to 122°F)
5
°
to 40°C (41
°
to 104°F)
-40
°
to 70°C (-40
°
to 158°F)
Relative humidity (non-condensing)
Operating
Non-operating
10% to 90% RH
5% to 95% RH
Note: Operating temperature has an altitude derating of 1
°
C per 300 M to 3000 M.
Table 5-4: Power Supply Requirements
Item Description
Model
Delta DPS-500GB H
PSU type
1U 500-watts
Input type
AC
continued
All manuals and user guides at all-guides.com