Removal and Replacement Procedures
2-22
HP ProLiant DL145 Generation 2 Server Maintenance and Service Guide
Figure 2-25: SCSI cable routing for low-profile controller boards phase 4
3.
Perform the post-installation procedures described on page 2-6
4.
Set up the SCSI configuration.
Refer to the documentation that came with the SCSI controller board for detailed
procedures.
To route the SCSI drive cables when the controller board is installed in the standard
height/full-length expansion slot:
1.
Connect the SCSI cable to the SCSI controller board:
a.
Connect the cable to the corresponding connector on the SCSI controller board.
b.
Fold the connector end of the SCSI cable in the manner illustrated in the following
figure.
c.
Attach a tie wrap (included in the SCSI cable option kit) in the 240 mm location of
the cable.
All manuals and user guides at all-guides.com