Specifications
C-GbE Interconnect Switch Interconnect Tray
Table 5-3: C-GbE Interconnect Switch Interconnect Tray Specifications
Feature Description
Dimensions
Height
3.3 cm (1.3 in)
Depth
28.7 cm (11.3 in)
Width
42.7 cm (16.8 in)
Capability IEEE
802.3, 802.3u, 802.3ab
Network transfer rate
10 Base-T (half-duplex)
10 Mbps
10 Base-T (full-duplex)
20 Mbps
100 Base-TX (half-duplex)
100 Mbps
100 Base-TX (full-duplex)
200 Mbps
1000 Base-TX (half-duplex)
1000 Mbps
1000 Base-TX (full-duplex)
2000 Mbps
Connector
(4) RJ-45 Uplink ports
(1) RJ-45 IA NIC port
(1) DB-9 IA Serial Local port
(2) RJ-45 Reserved
Cable support
10 Base-T
Categories 3, 4, or 5 UTP (2 or 4 pair); up to 100 m (328 ft)
100 Base-TX
Category 5 UTP (2 or 4 pair); up to 100 m (328 ft)
1000 Base-T
Category 5 UTP (4 pair); up to 100 m (328 ft)
Power requirements
4100 mA at 12 V, 5 Vaux at 500 mA, 5 V at 25 mA
Temperature
range
1
Operating
10
°
to 35
°
C (50
°
to 95
°
F)
Non-operating
-30° to 60°C (-22° to 140°F)
Relative humidity, noncondensing
2
Operating
20% to 80%
Non-operating
5% to 95%
1
Operating temperature has an altitude derating of 1°C per 304.8 (1.8
°
F per 1,000 ft). The
interconnect tray should not be exposed to direct sunlight. Upper operating limit is 3,048 m (10,000
ft) or 70Kpa/10.1 psia. Upper non-operating limit is 9,144 m (30,000 ft) or 30.3 KPa/4.4 psia.
2
Storage maximum humidity of 95% is based on a maximum temperature of 45°C (113
°
F). Altitude
minimum for storage is 70 KPa.
continued
5-4
HP ProLiant BL e-Class System Maintenance and Service Guide
HP CONFIDENTIAL
Codename: Kerr Part Number: 249066-004 Last Saved On: 5/12/03 3:10 PM