Removal and Replacement Procedures
CAUTION:
Integrated Administrator security settings are assigned to server blade bays, not
to server blades. If server blades change locations within the enclosure, Integrated
Administrator settings must also be adjusted to ensure accurate security. Refer to the
HP
ProLiant BL e-Class Integrated Administrator User Guide
for more information on security
settings.
6. Remove both hot-plug power supplies. See the “Hot-Plug Power Supplies” section in this
chapter.
7. Remove the interconnect tray from the enclosure. See the “Interconnect Tray” section in
this chapter.
8. Remove the enclosure from the rack. See the “Removing the Enclosure from the Rack”
section in this chapter.
9. Place the enclosure on a level, nonconductive surface.
10. Open the access door. See the “Opening the Access Door” section in this chapter.
11. Disconnect the enclosure status cable from the server blade backplane.
Figure 2-17: Disconnecting the enclosure status cable from the
server blade backplane
HP ProLiant BL e-Class System Maintenance and Service Guide
2-23