Removal and Replacement Procedures
Performing an Emergency Shutdown
Two methods are available for performing an emergency shutdown on a server blade:
Using the Integrated Administrator
•
•
Pressing and holding the server blade power button
Using the Integrated Administrator
You can perform an emergency shutdown of a ProLiant BL e-Class server blade by using the
“Power Off” option in the Integrated Administrator. To power down a server blade using the
Integrated Administrator, refer to the
HP ProLiant BL e-Class Integrated Administrator User
Guide
for detailed instructions.
Pressing and Holding the Server Blade Power Button
You can also perform an emergency shutdown of a ProLiant BL e-Class server blade by
pressing and holding the power button on the front of the server blade for 4 seconds.
CAUTION:
Performing an emergency shutdown on a server blade may result in the loss of
any unsaved data.
Repeat this step to power up a server blade.
Powering Down the Enclosure
Two different methods are available for powering down a ProLiant BL e-Class enclosure:
Graceful shutdown
•
•
•
•
Emergency shutdown
Performing a Graceful Shutdown
Two methods are available for performing a graceful shutdown on a ProLiant BL e-Class
enclosure:
Using the Integrated Administrator
Pressing the server blade power button
Using the Integrated Administrator
You can perform a graceful shutdown of a ProLiant BL e-Class enclosure by using the
“Power Off” option in the Integrated Administrator. To power down the enclosure using the
Integrated Administrator, refer to the
HP ProLiant BL e-Class Integrated Administrator User
Guide
for detailed instructions.
HP ProLiant BL e-Class System Maintenance and Service Guide
2-9
HP CONFIDENTIAL
Codename: Kerr Part Number: 249066-004 Last Saved On: 5/12/03 3:00 PM