Specifications
ProLiant BL e-Class Server Blade Enclosure
Table 5-1: ProLiant BL e-Class Server Blade Enclosure Specifications
Feature Description
Dimensions
Height
13.1 cm (5.15 in)
Depth
68.6 cm (27 in)
Width
44.5 cm (17.5 in)
Weight with patch panel
No server blades
26.76 kg (59 lb)
20 server blades
42.64 kg (94 lb)
Input requirements
Rated input voltage
100 to 127 VAC
200 to 240 VAC
Rated input frequency
47 to 63 Hz
Rated input current
8.5A at 120 VAC
4.3A @ 240 VAC
Rated input power
1000 W
BTUs per hour
3416
Temperature range
1
Operating
10
°
to 35
°
C (50
°
to 95
°
F)
Shipping, 72 hours
-40
°
to 60
°
C (-40
°
to 140
°
F)
Relative humidity
2
(noncondensing)
Operating
10% to 90%
Non-operating
10% to 95%
1
The unit must be capable of functioning in an operating environment of 10° to 35°C. There is an
altitude derating of 1
°
C per 304.8 m (1.8
°
F per 1,000 ft) above sea level, up to a maximum of 3,048
m (10,000ft). In a shipping environment (up to 72 hours), the unit shall withstand temperatures of up
to 60
°
C (140
°
F) and down to -40
°
C (-40
°
F) and altitudes up to 9100 m. In a storage environment (up
to one year), the unit shall withstand temperatures of up to 60
°
C (140
°
F) and down to -20
°
C (-4
°
F)
and altitudes up to 3,048 m.
2
In an operating mode, the unit must work from 10% to 90% relative humidity (non-condensing)
across the operating temperature range. In a non-operating mode, the chassis must be able to
withstand humidity of 10% to 95% relative humidity (non-condensing) across the temperature range
.
5-2
HP ProLiant BL e-Class System Maintenance and Service Guide
HP CONFIDENTIAL
Codename: Kerr Part Number: 249066-004 Last Saved On: 5/12/03 3:10 PM