Table 4 System power specifications
(continued)
Parameter
+12VSB /2.5A MAX
+12VSB /2.5A MAX
+12VSB /2.5A MAX
If an overload triggers the power supply overload protection, the system is immediately powered
off. To reset the power supply unit:
1.
Disconnect the power cord.
2.
Determine what caused the overload by contacting an HP support representative.
3.
Reconnect the power cord.
4.
Reboot the system.
NOTE:
If an overload occurs twice, an undetected short circuit exists.
When you use the front panel power button to turn off the server, power consumption falls below
the low power consumption, but does not reach zero. To reach zero power consumption in "off"
mode, disconnect all power supplies from their power sources.
Power consumption and cooling
The power consumptions listed in
are valid for the configuration shown. Please
use the HP Power Advisor tool to obtain power information for other configurations or utilization
factors.
Table 5 Standard configuration power consumption
Power consumption
Standard configuration
1228 Btu/h (maximum)
360 W (maximum)
One 1.46 GHz quad-core processor, 4 GB memory,
one 1200 W power supply, and one SAS disk drive
HP Confidential
Server electrical specifications
15