![HP Integrity NonStop NS-series Operation Manual Download Page 199](http://html.mh-extra.com/html/hp/integrity-nonstop-ns-series/integrity-nonstop-ns-series_operation-manual_164441199.webp)
Starting and Stopping the System
HP Integrity NonStop NS-Series Operations Guide — 529869-005
15 -23
Opening Startup Event Stream and Startup TACL
Windows
1. Select
Start > OutsideView > OutsideView
. The OutsideView dialog box appears.
2. Select
Session > New
. The New Session Properties dialog box appears.
3. On the Session tab, in the Session Caption box, type a session caption name such
as Startup Events or Startup TACL.
4. Click
IO Properties
. The TCP/IP Properties dialog box appears.
5. Type the DNS name or IP address of the maintenance entity (ME) or integrated
maintenance entity (IME), followed by a space, and the port number of the window
type (303 for the startup event stream window, and 301 for the startup TACL
window).
For example, for the startup event stream window:
me-system1
-
G100-M02
303
me-system1
-
G100-M03 303
192.231.36.2 303
Then, for the startup TACL window:
me-system1
-
G100-M02
301
me-system1
-
G100-M03 301
192.231.36.2 301
6. Click
OK
. The TCP/IP Properties dialog box closes, and you are returned to the
New Session Properties dialog box.
7. Click
OK
. The startup event stream window or startup TACL window appears. A
TACL prompt appears in the startup TACL window.
Consult the OSM Event Viewer for any important system startup messages logged to
the EMS log that you might have missed while opening the terminal-emulation
windows.