HP Indigo press ws4000 Cluster 1 procedures
proprietary and confidential
CA293-00600, Rev 00
page 160 of 221
Figure 183 Loosening the motor bracket
a. Use an M6 Allen key to loosen the four Allen screws securing the gear.
b. Move the gear to loosen or tighten the belt as necessary.
c. Tighten
the
screws.
10. Repeat steps 5 through 9 until an average tension reading of 87.6 – 93.6
Hz (for old motor) or 104.7 – 109.8 Hz (for new motor) is obtained.
Installing the anti-drip kit assembly
The procedure below involves the removal of certain parts in the Input side of the
press, and their replacement with new parts.
Prerequisites
The following kit parts are required for installation:
Figure 184 Parts to be installed
In addition, a cable clamp and a variety of fastening hardware are included in the
FCO kit dripping for ws4000 (CA292-00311).
Note:
It is not necessary to install the new gutter (CA240-11250) in presses that
have had
the Cluster 1 FCO (CA293-00600) installed.
Part 2: new catch tray
(CA244-01190)
Part 1: New IR sensor bracket
(CA244-00310)
Part 3: new gear guard
(CA245-03210)
Part 4: New gutter
(CA240-11250)