HP Indigo press ws4000 Cluster 1 procedures
proprietary and confidential
CA293-00600, Rev 00
page 136 of 221
•5. Repeat steps 1-3 for each of the other three screws that secure the drive
motor to the plate.
The following procedures describe installing the Output assembly.
Note:
This procedure requires two people.
•1. Close and secure the GDB panel cover.
•2. Put the top panel gasket in place.
•3. Lift the Output assembly unit and set it on the pins on the front and rear
walls of the press.
Note:
Be careful that all cables are pulled out of the way and do not get caught between
the Output assembly walls and the press.
•4. Tighten the three screws on the front wall and the three screws on the rear
wall to secure the Output assembly unit in the press. Alternate the
tightening of the screws to ensure that the assembly fits evenly in the
press.
Figure 154 Reconnecting encoder and power connectors
•5. Plug the encoder and power connectors onto the FP motor.
•6. Connect the Upper Nip interlock UL cable.