296
N:\mkt\MANUALS\HP8924C\APPMOD\BOOK\chapters\amcproc.fb
Chapter 9, 264 Using the Analog Call Processing Subsystem
Using the CALL CONTROL Screen to test AMPS Authentication
13. Select
SSD Upd
from the
CC Order
field. The Access annunciator light will light
while the SSD Update order is in progress. If the mobile station responds properly on
the reverse control-channel, “
SSD Update Order Successful
” will be dis-
played in the upper right-hand portion of the CALL CONTROL screen. The test set and
the mobile station now share common secret data and further call processing functions
with authentication can be tested. If the order failed, then “
SSD Update Order
Failed
” will appear on the upper right-hand portion of the CALL CONTROL screen.
Page a Mobile Station with Authentication
Paging A Mobile
Station That Has
Registered With The
Test Set
1. Ensure that the Test Set is in the active state.
See "Turn On The Test Set’s Control
for information on how to activate the Test Set.
2. Connect the mobile station to the Test Set as shown in
bile Station to the Test Set," on page 269
.
3. Turn on the mobile station.
4. If the CALL CONTROL screen is not displayed, select
CALL CNTL
from the
To
Screen
menu. The CALL CONTROL screen will be displayed.
5. Position the cursor on the
Display
field and select
Data
.
6. Ensure that the mobile station has registered with the Test Set.
Processing with Authentication"
7. for information on how to register the mobile station.
8. Select the
Page
field. The
Page
annunciator will light while the Test Set pages the
mobile on the forward control channel. If the mobile station responds properly on the
reverse control-channel the message
RECC Return
will flash momentarily in the up-
per right-hand corner of the CALL CONTROL screen. The
Access
annunciator will
then light while the Test Set sends the mobile station an alert order on the assigned
voice channel. The mobile station should ring.
9. Press the SEND key on the mobile station. The
Connect
annunciator will light if the
mobile station properly signals the Test Set. The mobile station is now connected to the
Test Set on the assigned voice channel. The
Voice Channel Assignment
fields
will be updated, that is, any “-” in the left-hand fields will be replaced with appropriate
information. If page with authentication was successful, “
Page w/Auth success-
ful
” will be displayed in the upper right-hand portion of the CALL CONTROL
screen. If page with authentication failed, then “
Page w/Auth failed
” will be dis-
played in the upper right-hand portion of the CAll CONTROL Screen.
Originate a Call with Authentication
1. Ensure that the Test Set is in the active state.
See "Turn on the Test Set’s Control
2. Connect the mobile station to the Test Set as shown in
bile Station to the Test Set," on page 269
.
3. Turn on the mobile station.
4. If the CALL CONTROL screen is not displayed, select
CALL CNTL
under the
To
Screen
menu. The CALL CONTROL screen will be displayed.