Battery-Backed Write Cache Enabler Option
The Battery-Backed Write Cache Enabler, along with the battery module,
provides transportable data protection, increases overall controller performance,
and maintains any cached data for up to 72 hours. The NiMH batteries in the
battery module are continuously recharged through a trickle-charging process
whenever the system power is on. Under normal operating conditions, the battery
module lasts for 3 years before replacement is necessary.
CAUTION: To prevent damage to the equipment or server
malfunction, do not add or remove the battery module while an array
capacity expansion, RAID level migration, or stripe size migration is in
progress.
IMPORTANT: The battery module may have a low charge when
installed. In this case, a POST error message is displayed when the
server is powered up, indicating that the battery module is temporarily
disabled. No action is necessary on your part. The internal circuitry
automatically recharges the batteries and enables the battery module.
This process may take up to 4 hours. During this time, the array
controller will function properly, but without the performance advantage
of the battery module.
NOTE: The data protection and the time limit also apply if a power
outage occurs. When power is restored to the system, an initialization
process writes the preserved data to the hard drives.
To install the Battery-Backed Write Cache Enabler:
1. Power down the server ("Powering Down the Server" on page
25
).
2. Extend the server from the rack, if applicable ("Extending the Server from
the Rack" on page
26
).
3. Remove the access panel ("Removing the Access Panel" on page
27
).
4. Align the battery module over the quarter-turn fasteners.
Summary of Contents for DL360 - ProLiant - Photon
Page 24: ......
Page 30: ...30 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide ...
Page 42: ......
Page 94: ...94 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide ...
Page 97: ...Troubleshooting 97 ...
Page 99: ...Troubleshooting 99 ...
Page 101: ...Troubleshooting 101 ...
Page 104: ...104 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide ...
Page 222: ......
Page 236: ......
Page 241: ...Acronyms and Abbreviations 241 VHDCI very high density cable interconnect WOL Wake on LAN ...
Page 242: ......