180
HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide
Description: You have exceeded the maximum number of drives supported for
this controller, and the connected controller was not part of the original array
configuration.
Action:
1. Upgrade the firmware on this controller.
2. If the problem persists:
Replace this controller with the original controller.
-Or-
Replace this controller with a new controller that supports the number of
drives in the array.
Swapped Cables or Configuration Error Detected. A Drive Rearrangement...
...was attempted while an expand operation was running. This is an unsupported operation.
SOLUTION: Power down system then move drives back to their original location. Power
on system and wait for the expand operation to complete before attempting a drive
rearrangement.
Description: One or more drive locations were changed while an expand
operation was in progress.
Action:
1. Power down the server.
2. Place the drives in their original locations.
3. Restart the server, and then complete the expand operation.
4. Move the drives to their new locations after the expand operation is
completed.
Swapped Cables or Configuration Error Detected. An Unsupported Drive
Arrangement Was Attempted...
...SOLUTION: Power down system then move drives back to their original location.
Summary of Contents for DL360 - ProLiant - Photon
Page 24: ......
Page 30: ...30 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide ...
Page 42: ......
Page 94: ...94 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide ...
Page 97: ...Troubleshooting 97 ...
Page 99: ...Troubleshooting 99 ...
Page 101: ...Troubleshooting 101 ...
Page 104: ...104 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide ...
Page 222: ......
Page 236: ......
Page 241: ...Acronyms and Abbreviations 241 VHDCI very high density cable interconnect WOL Wake on LAN ...
Page 242: ......