Troubleshooting
199
104-ASR Timer Failure
Audible Beeps: None
Possible Cause: System board failure.
CAUTION: Only authorized technicians trained by HP should
attempt to remove the system board. If you believe the system board
requires replacement, contact HP Technical Support before proceeding.
Action: Run Insight Diagnostics ("HP Insight Diagnostics" on page
80
) and
replace failed components as indicated.
162-System Options Not Set
Audible Beeps: 2 long
Possible Cause: Configuration is incorrect. The system configuration has
changed since the last boot (addition of a hard drive, for example) or a loss of
power to the real-time clock has occurred. The real-time clock loses power if the
onboard battery is not functioning correctly.
Action: Press the F1 key to record the new configuration. Run the server setup
utility to change the configuration. If this message persists, you may need to
replace the onboard battery.
163-Time & Date Not Set
Audible Beeps: 2 long
Possible Cause: Invalid time or date in configuration memory.
Action: Run the server setup utility and correct the time or date.
Summary of Contents for DL360 - ProLiant - Photon
Page 24: ......
Page 30: ...30 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide ...
Page 42: ......
Page 94: ...94 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide ...
Page 97: ...Troubleshooting 97 ...
Page 99: ...Troubleshooting 99 ...
Page 101: ...Troubleshooting 101 ...
Page 104: ...104 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide ...
Page 222: ......
Page 236: ......
Page 241: ...Acronyms and Abbreviations 241 VHDCI very high density cable interconnect WOL Wake on LAN ...
Page 242: ......