Troubleshooting
157
Accelerator Error Log
Description: List of the last 32 parity errors on transfers to or from the memory
on the array accelerator board. Displays starting memory address, transfer count,
and operation (read and write).
Action: If many parity errors are listed, you may need to replace the array
accelerator board.
Accelerator Parity Read Errors: X
Description: Number of times that read memory parity errors were detected
during transfers from memory on array accelerator board.
Action: If many parity errors occurred, you may need to replace the array
accelerator board.
Accelerator Parity Write Errors: X
Description: Number of times that write memory parity errors were detected
during transfers to memory on the array accelerator board.
Action: If many parity errors occurred, you may need to replace the array
accelerator board.
Accelerator Status: Cache was Automatically Configured During Last Controller
Reset
Description: Cache board was replaced with one of a different size.
Action: No action is required.
Accelerator Status: Data in the Cache was Lost...
...due to some reason other than the battery being discharged.
Summary of Contents for DL360 - ProLiant - Photon
Page 24: ......
Page 30: ...30 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide ...
Page 42: ......
Page 94: ...94 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide ...
Page 97: ...Troubleshooting 97 ...
Page 99: ...Troubleshooting 99 ...
Page 101: ...Troubleshooting 101 ...
Page 104: ...104 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide ...
Page 222: ......
Page 236: ......
Page 241: ...Acronyms and Abbreviations 241 VHDCI very high density cable interconnect WOL Wake on LAN ...
Page 242: ......