User String:
Com1 Baud:9600 Flow:SOFTWARE Mode:THROUGH Modem:DISABLED
Rmc:ENABLED
Logout Timer: 20 minutes
Voltage Status: OK
Thermal Status: OK Thermal Shutdown: Enabled
Warning Threshold: 60.00°C Fatal/Power-Down Threshold:
65.00°C
Fan Status: OK Fan Shutdown: Enabled
PCI Riser: Installed
POST DPR: OK NVRAM: OK GPIOs: OK LM75: OK
Watchdog Timer: Disabled Watchdog Reboot: Disabled
RMC>
A typical alert situation might be as follows:
•
The RMC detects an alarm condition, such as over temperature failure.
•
The RMC dials your pager and sends a message identifying the system.
•
You dial the system from a remote serial terminal.
•
You enter the RMC, check system status with the
env
command, and, if the situation
requires, power down the managed system. (In many cases, a failure may have already
powered the system down.)
•
When the problem is resolved, you power up and reboot the system.
Using the Remote Management Console
6-27