Control panel message
Description
Recommended action
2217-ME Firmware Version request failure
ME firmware is not properly responding to
BIOS query for version information.
1.
Reboot the computer.
2.
If the error persists, update to the latest
BIOS version and ME firmware
version.
3.
If the error still persists, replace the
system board.
2218-ME Firmware Version should be
updated
ME firmware must be updated to match
current functionality contained in the system
BIOS.
1.
Update to the latest ME firmware
version.
2.
If the error persists and system BIOS
has been recently updated, restore
previous system BIOS version.
3.
If the error still persists, replace the
system board.
2219-USB Key Provisioning file has invalid
header identifier
Provisioning file contained on the USB key
has been corrupted or is not a valid version
for the current ME firmware.
1.
Recreate the provisioning file using
third party management console
software.
2.
If the error persists and system BIOS
has been recently updated, restore
previous system BIOS version.
Otherwise, update the ME firmware
version.
3.
If the error still persists, replace the
system board.
2220-USB Key Provisioning file has
mismatch version
Provisioning file contained on the USB key
is not a valid version for the current ME
firmware.
1.
Reboot the computer.
2.
If the error persists and system BIOS
has been recently updated, restore
previous system BIOS version.
Otherwise, update the ME firmware
version.
3.
If the error still persists, replace the
system board.
2230-General error during MEBx execution
Error occurred during MEBx execution
which fails into the “General” grouping.
Status information displayed along with the
error provides further clarity into the failure.
MEBx handles transference of information
between the system BIOS and ME
firmware.
1.
Reboot the computer.
2.
If the error persists, update to the latest
BIOS version and ME firmware
version.
3.
If the error still persists, replace the
system board.
2231-ME error during MEBx execution
Error occurred during MEBx execution
which fails into “ME” grouping.
1.
Reboot the computer.
2.
If the error persists, update to the latest
BIOS version and ME firmware
version.
3.
If the error still persists, replace the
system board.
Table F-1
Numeric Codes and Text Messages (continued)
POST Numeric Codes and Text Messages 219