![HP 3100 v2 Series Command Reference Manual Download Page 14](http://html.mh-extra.com/html/hp/3100-v2-series/3100-v2-series_command-reference-manual_165751014.webp)
7
View
Any view
Default level
1: Monitor level
Parameters
interface-type
: Specifies an interface type.
interface-number
: Specifies an interface number.
brief
: Displays brief interface information. If you do not specify this keyword, the command displays
detailed interface information.
down
: Displays information about interfaces in down state and the causes. If you do not specify this
keyword, this command displays information about interfaces in all states.
description
: Displays complete interface descriptions. If you do not specify this keyword, the
command displays only the first 27 characters of each interface description.
|
: Filters command output by specifying a regular expression. For more information about regular
expressions, see
Fundamentals Configuration Guide
.
begin
: Displays the first line that matches the specified regular expression and all lines that follow.
exclude
: Displays all lines that do not match the specified regular expression.
include
: Displays all lines that match the specified regular expression.
regular-expression
: Specifies a regular expression, a case-sensitive string of 1 to 256 characters.
Description
Use
display interface
to display Ethernet interface information.
If no interface type is specified, this command displays information about all interfaces.
If an interface type is specified but no interface number is specified, this command displays
information about all interfaces of that type.
Related commands:
interface
.
Examples
# Display detailed information about interface Ethernet 1/0/1.
<Sysname>display interface ethernet 1/0/1
Ethernet1/0/1 current state: DOWN
IP Packet Frame Type: PKTFMT_ETHNT_2, Hardware Address: 00e0-fc00-9877
Description: Ethernet1/0/1 Interface
Loopback is not set
Media type is twisted pair
Port hardware type is 100_BASE_T
Unknown-speed mode, unknown-duplex mode
Link speed type is autonegotiation, link duplex type is autonegotiation
Flow-control is not enabled
The Maximum Frame Length is 2048
Broadcast MAX-ratio: 100%
Unicast MAX-ratio: 100%
Multicast MAX-ratio: 100%
PVID: 1
Mdi type: auto
Port link-type: access