33 of 61
Indesit
Company
Service Manual UK
English
TEMPERATURE TABLES
REFRIGERATION DAMPER CONDITIONS
If conditions differ, check the damper and vent for ice blockages. If
the fridge sensor fails the main board preset parameters will operate
the Evaporator Fan for 15 minutes together with opening of the
damper and then turn it OFF for 30 minutes whilst closing the
damper.
FREEZER COMPRESSOR CONDITIONS
NTC sensor (thermistor) is located on the left liner inside the freezer
compartment. It controls the compressor and evaporator fan ON
times according to the freezer temperatures.
Refrigerator
Display (°C)
Damper ON (°C)
Damper OFF (°C)
6
7.5
5.5
5
6.5
4.5
4
5.0
3.5
3
4.0
2.5
2
3.0
1.5
FREEZER Temperature Sensor
Freezer Display
Compressor
ON (°C)
Compressor OFF
(°C)
-18
-18
-20
-19
-19
-21
-20
-20
-22
-21
-21.5
-23.5
-22
-22.5
-24.5
-23
-23.5
-25.5
-24
-24.5
-26.5
Super Freeze
-18 / -24
Continuous Running for 24 hours
NTC sensor (thermistor) is
Fig. 11
located in the refrigerator
compartment to control the
temperature by means of the
evaporator fan and the
damper.
The freezer sensor is at
fault if the resistance value
is higher than 110 KOhm or
lower than 500 ohm.
Note: The main board preset
parameters will keep the
appliance working efficiently.
Fig. 12