17 of 61
Indesit
Company
Service Manual UK
English
ICE SOLENOID WATER VALVE MANAGEMENT (2010 DF MODELS):
The icemaker water solenoid valve will be automatically controlled and driven by the Icemaker.
The flow rate for the icemaker water valve:1.13 litres per minute (140cc per 7.5 s11cc –17cc)
Supply voltage (nominal):
12V
Motor power dissipation:
8 W
Ice production per 24 Hours:
Approximately 200 ice cubes
Condition to start ice production:
-9°C appliance temperature for min. 2 hours
Condition to stop ice production:
-10°C temperature in the mould (ice-sensor)
(The above could vary depending on water pressure, usage of appliance and temperature etc.).
ICE SOLENOID WATER VALVE MANAGEMENT (2011 NDF MODELS)
The icemaker water valve will be automatically controlled and driven by the Main Power Module.
The flow rate for the icemaker water valve:
1.51 litres per minute
Opening time of the icemaker water valve:
5 seconds = ~100cc (+/- 3cc)
Ice valve ALARM indication for opening time:
20 seconds
Water pressure range with filter cartridge:
2.07 bar till 8.27 bar
Water pressure range without water filter:
1.38 bar till 8.27 bar
General Requirements
Supply voltage (nominal):
12V
Motor power dissipation:
8 W
Ice production per 24 Hours:
0.8 kg (six or seven loads)
Condition to start ice production:
-10°C appliance temperature for min. 2 hours
Condition to stop ice production:
-9°C temperature in the mould (ice-sensor)