31
31
E1CG4880210
E1CG4880210
Fig. 15
Fig. 15
Top Panel
Top Panel
Screw
Screw
Unit Cover
Unit Cover
If the non-rewirable plug has been cut from the power supply cord, it must be disposed of.
If the non-rewirable plug has been cut from the power supply cord, it must be disposed of.
There should be no attempt to reuse it. Inserting such a plug into a socket elsewhere presents
There should be no attempt to reuse it. Inserting such a plug into a socket elsewhere presents
a serious risk of electrical shock.
a serious risk of electrical shock.
* The non-rewirable plug must never be used without a fuse cover being fitted.
* The non-rewirable plug must never be used without a fuse cover being fitted.
The correct replacement for the detachable fuse cover is identifiable from the manufacturer’s
The correct replacement for the detachable fuse cover is identifiable from the manufacturer’s
reference number stamped on the plug.
reference number stamped on the plug.
Supply of replacement fuse covers can be obtained from Hoshizaki Parts/Service Centres.
Supply of replacement fuse covers can be obtained from Hoshizaki Parts/Service Centres.
Fuses should be rated at 13A and approved to BS 1362.
Fuses should be rated at 13A and approved to BS 1362.
6. REMOTE CONDENSER UNIT (Remote Air-Cooled Model Only)
6. REMOTE CONDENSER UNIT (Remote Air-Cooled Model Only)
[a] UNPACKING
[a] UNPACKING
1) Unpack and remove shipping carton, tape(s) and
1) Unpack and remove shipping carton, tape(s) and
packing.
packing.
2) Remove the Top Panel.
2) Remove the Top Panel.
3) Check that the refrigerant lines do not rub or touch
3) Check that the refrigerant lines do not rub or touch
lines or other surfaces, and that the fan blade
lines or other surfaces, and that the fan blade
turns freely.
turns freely.
4) Recommended parts and materials listed below
4) Recommended parts and materials listed below
will be required.
will be required.
Cord
Cord
17 AWG (1.0 mm
17 AWG (1.0 mm
2
2
) three-wire cord will be required for the Fan Motor wiring between
) three-wire cord will be required for the Fan Motor wiring between
the icemaker and the Condenser Unit (L+N+ ).
the icemaker and the Condenser Unit (L+N+ ).
Copper Tubing
Copper Tubing
Phosphorus deoxidized copper tubing. Two tubings of the same size will be required
Phosphorus deoxidized copper tubing. Two tubings of the same size will be required
for refrigerant lines. Mark them for a distinction between the gas line and liquid line to
for refrigerant lines. Mark them for a distinction between the gas line and liquid line to
prevent misconnection.
prevent misconnection.
9.52 (OD) x 7.93 (ID) - Gas
9.52 (OD) x 7.93 (ID) - Gas
9.52 (OD) x 7.93 (ID) - Liquid
9.52 (OD) x 7.93 (ID) - Liquid
Pipe Insulation (for gas and liquid pipes)
Pipe Insulation (for gas and liquid pipes)
To withstand temperatures up to 120°C.
To withstand temperatures up to 120°C.
Bolt
Bolt
Four M8 Hexagon Bolts for securing the Condenser Unit.
Four M8 Hexagon Bolts for securing the Condenser Unit.
5) Do not remove the Unit Covers before finishing installation, to prevent damage to the air-
5) Do not remove the Unit Covers before finishing installation, to prevent damage to the air-
cooled Condenser.
cooled Condenser.
Summary of Contents for IM-240AME
Page 6: ...2 2 E1CG4880210 E1CG4880210 b IM 240DWME Water cooled b IM 240DWME Water cooled ...
Page 7: ...3 3 E1CG4880210 E1CG4880210 c IM 240DSME Remote Air cooled c IM 240DSME Remote Air cooled ...
Page 8: ...4 4 E1CG4880210 E1CG4880210 d IM 240XME Air cooled d IM 240XME Air cooled ...
Page 9: ...5 5 E1CG4880210 E1CG4880210 e IM 240XWME Water cooled e IM 240XWME Water cooled ...
Page 10: ...6 6 E1CG4880210 E1CG4880210 f IM 240XSME Remote Air cooled f IM 240XSME Remote Air cooled ...
Page 11: ...7 7 E1CG4880210 E1CG4880210 g IM 240AME Air cooled g IM 240AME Air cooled ...
Page 62: ...58 58 E1CG4880210 E1CG4880210 b IM 240DWME IM 240XWME b IM 240DWME IM 240XWME ...
Page 63: ...59 59 E1CG4880210 E1CG4880210 c IM 240DSME IM 240XSME c IM 240DSME IM 240XSME ...
Page 64: ...60 60 E1CG4880210 E1CG4880210 d IM 240AME d IM 240AME ...