28
28
E1CG4880210
E1CG4880210
Fig. 10
Fig. 10
Fig. 11
Fig. 11
Lower Unit
Lower Unit
Extension
Extension
Washer
Washer
Bolt
Bolt
Bolt
Bolt
Drain Pipe Collar
Drain Pipe Collar
Packing
Packing
Drain Pan
Drain Pan
Extension
Extension
Drain Hole
Drain Hole
Bin Control Switch
Bin Control Switch
Drain Pan
Drain Pan
Handle with care
Handle with care
Frame
Frame
Bin Control Switch
Bin Control Switch
Screw
Screw
Washer
Washer
4. STACKING ICEMAKERS - IM-240D, IM-240X ONLY
4. STACKING ICEMAKERS - IM-240D, IM-240X ONLY
WARNING
WARNING
Check the icemaker models. A D-type icemaker and an X-type icemaker will
Check the icemaker models. A D-type icemaker and an X-type icemaker will
be required for stacking two icemakers. A D-type icemaker and two X-type
be required for stacking two icemakers. A D-type icemaker and two X-type
icemakers will be required when stacking three icemakers. The D-type icemaker
icemakers will be required when stacking three icemakers. The D-type icemaker
is designed for the upper unit, and the X-type for the middle and lower units.
is designed for the upper unit, and the X-type for the middle and lower units.
The D-type and X-type icemakers are provided with two different types of Bin
The D-type and X-type icemakers are provided with two different types of Bin
Control Switch. Use the Bin Control Switch of the lower X-type icemaker only
Control Switch. Use the Bin Control Switch of the lower X-type icemaker only
when stacking icemakers. The Bin Control Switch must be removed from the
when stacking icemakers. The Bin Control Switch must be removed from the
upper (and middle) units. Connection of the Bin Control from the lower (and
upper (and middle) units. Connection of the Bin Control from the lower (and
middle) to the upper unit will require additional connecting leads which are
middle) to the upper unit will require additional connecting leads which are
supplied with the X-type icemaker. Misconnection or no connection may cause
supplied with the X-type icemaker. Misconnection or no connection may cause
serious damage to the icemaker units, resulting in failure.
serious damage to the icemaker units, resulting in failure.
1) Prepare and position the Storage Bin as detailed in 1) and 2) in “3. INSTALLATION”.
1) Prepare and position the Storage Bin as detailed in 1) and 2) in “3. INSTALLATION”.
2) Remove the icemaker panels. The Rear Panel is not required to be removed for installation.
2) Remove the icemaker panels. The Rear Panel is not required to be removed for installation.
See “1. UNPACKING”.
See “1. UNPACKING”.
3) Move the icemaker carefully to prevent damage to the icemaker frame.
3) Move the icemaker carefully to prevent damage to the icemaker frame.
4) Remove the shipping tape holding the Drain
4) Remove the shipping tape holding the Drain
Pan.
Pan.
5) Attach the lower unit (X-type) on the top of the
5) Attach the lower unit (X-type) on the top of the
Storage Bin. See Fig. 10.
Storage Bin. See Fig. 10.
6) Secure the lower unit with the two bolts and two
6) Secure the lower unit with the two bolts and two
plastic washers provided. See Fig. 10.
plastic washers provided. See Fig. 10.
7) Remove the shipping tape holding the Bin
7) Remove the shipping tape holding the Bin
Control Switch on the Drain Pan. Attach the
Control Switch on the Drain Pan. Attach the
Bin Control Switch to the frame located at the
Bin Control Switch to the frame located at the
left bottom of the condensing unit, and secure
left bottom of the condensing unit, and secure
it using the two screws and the two washers
it using the two screws and the two washers
provided. See Fig. 11.
provided. See Fig. 11.
8) [P-200SD]
8) [P-200SD]
Align the drain hole and the drain pan hole.
Align the drain hole and the drain pan hole.
Insert the Packing (bin accessory) and fasten
Insert the Packing (bin accessory) and fasten
the Drain Pipe Collar (bin accessory) tightly,
the Drain Pipe Collar (bin accessory) tightly,
within the recommended torque of 39.2 N·m.
within the recommended torque of 39.2 N·m.
See Fig. 10.
See Fig. 10.
Summary of Contents for IM-240AME
Page 6: ...2 2 E1CG4880210 E1CG4880210 b IM 240DWME Water cooled b IM 240DWME Water cooled ...
Page 7: ...3 3 E1CG4880210 E1CG4880210 c IM 240DSME Remote Air cooled c IM 240DSME Remote Air cooled ...
Page 8: ...4 4 E1CG4880210 E1CG4880210 d IM 240XME Air cooled d IM 240XME Air cooled ...
Page 9: ...5 5 E1CG4880210 E1CG4880210 e IM 240XWME Water cooled e IM 240XWME Water cooled ...
Page 10: ...6 6 E1CG4880210 E1CG4880210 f IM 240XSME Remote Air cooled f IM 240XSME Remote Air cooled ...
Page 11: ...7 7 E1CG4880210 E1CG4880210 g IM 240AME Air cooled g IM 240AME Air cooled ...
Page 62: ...58 58 E1CG4880210 E1CG4880210 b IM 240DWME IM 240XWME b IM 240DWME IM 240XWME ...
Page 63: ...59 59 E1CG4880210 E1CG4880210 c IM 240DSME IM 240XSME c IM 240DSME IM 240XSME ...
Page 64: ...60 60 E1CG4880210 E1CG4880210 d IM 240AME d IM 240AME ...