Suction Pressure and Evaporator Temp.
50/60Hz
Ambient Temp. (°C)
10
21
32
38
MODEL
Water Temp. (°C)
10
15
21
32
Suction Pressure
Peak (bar)
3.0
4.0
4.5
5.5
IM-240 “M” type
(R404A)
Evaporator Inlet
Temp. (°C)
-20
-19
-18
-17
Note: The above data are only for reference in servicing. Actual readings may be
slightly different for each product.
Suction Pressure = Peak readings in freezing cycle
Evaporator Inlet Temp. = 5 minutes before completion of freezing cycle