VISIONPRO
®
8000 WITH REDLINK™
68-0312—03
124
Fig. 321. Geothermal radiant heat with geothermal forced air and backup heat using separate transformer for the radiant
heat.
1U1, U2 or U3 terminals must be used for geothermal radiant heat (ISU 201). Thermostat allows 2 stages of radiant heat—geo-
thermal (stage 1) and boiler (stage 2).
2“U” terminals are normally open dry contacts when set up for geothermal radiant heat. You must install a field jumper if radiant
heat is powered by system transformer. Do NOT install a field jumper if radiant heat has its own transformer.
3L/A terminal sends continuous output when thermostat is set to EM HEAT mode except when set up for Economizer or TOD. See
“Economizer Module Wiring Diagrams” beginning on page 132.
4Y2 used with heat pumps that have 2 compressor stages.
NOTE: For setup and operation, see “Geothermal Radiant Heat” beginning on page 78.
O/B
AUX1
AUX2
O
W1
W2
Y
Y2
G
R
C
O
Y
Y2
R
C
TRANSFORMER
24
VAC
120
VAC
L/A
TO THERMOSTAT
THERMOSTAT/EIM
HEAT PUMP
FURNACE
HEAT PUMP
M34525
RADIANT HEAT
ZONE MODULE
VALVE
PUMP
END SWITCH
C
R
3
4
1