Configuration Parameter Definitions
Pen Parameters Set Up Group
Release M
DR4500A Classic Series Circular Chart Recorder With or Without Control Product Manual
87
April 2017
Lower Display
Prompt
Upper Display
Range of Setting or Selection
Parameter Definition
PENnON
(n = 1 or 2)
0 to 100%
PEN CHART POSITION FOR
ON
EVENT
— This is the
event marker configuration using digital inputs.
Select the chart position where pen 1 (pen 2) is to mark
(trace) occurrence of an ON event.
Prompt only appears if DGTL1 or 2 is selected as pen
1 (pen 2) input.
PENnOFF
(n = 1 or 2)
0 to 100%
PEN CHART POSITION FOR
OFF
EVENT
— This is
the event marker configuration using digital inputs.
Select the chart position where pen 1 (pen 2) is to mark
(trace) occurrence of an OFF event.
Prompt only appears if DGTL1 or 2 is selected as
pen 1 (pen 2) input.
Repeat this procedure for PEN 2 configuration.