GSMBR / iGSMBR Installation and Setup Guide
6-2
RDR1 RDR2 RDR3
OK OK OK
A summary of the tests is displayed after Redir 3 is tested. The
example shows that the tests of all three connection points, or
Redirs, were successful. If an error occurred at any point, the
summary will display "FAIL" under the faulty Redir.
Possible Errors Running Network Diagnostics
Errors may occur either while tracing the connection to a given Redir or while testing the
service at a given Redir. The following list highlights the most common errors. Please
contact the AlarmNet Technical Assistance Center (TAC) for help regarding any errors NOT
listed below:
Possible Errors
Testing Redir
x
FAIL before Gtwy
While tracing the connection to Redir x, the trace fails before ever
reaching the local gateway (router).
Testing Redir
x
FAIL at Gtwy
While tracing the connection to Redir x, the trace fails after reaching
the local gateway (router).
Testing Redir
x
FAIL at Pvt IP
While tracing the connection to Redir x, the trace fails after reaching
the private IP.
Testing Redir
x
FAIL on IP Addr
While tracing the connection to Redir x, the trace fails after reaching
the public IP.
Redir
x
ERR:Proxy 18
After a successful trace to Redir x, the test of the network service
timed out without a response.
Summary of Contents for AlarmNet GSMBR
Page 2: ......
Page 38: ...GSMBR iGSMBR Installation and Setup Guide 3 22 ...
Page 50: ...GSMBR iGSMBR Installation and Setup Guide A 2 ...
Page 54: ...GSMBR iGSMBR Installation and Setup Guide C 2 ...
Page 57: ...NOTES ...
Page 58: ...NOTES ...
Page 59: ...NOTES ...
Page 60: ...NOTES ...
Page 61: ...NOTES ...
Page 62: ...NOTES ...