
GSMBR / iGSMBR Installation and Setup Guide
2-4
•
For EOLR supervised N.O. or N.C. voltage tripping, the resultant voltage change from a
tripped zone is detected.
NOTE:
LYNXR and LYNXR-EN have a designated V– trigger output (LRR / AAV).
Connect a wire from the triggering source (bell output, voltage trigger, etc.) of the control
panel to the zone input of the module, and connect a common ground between the module
and control panel. See the zone connection examples in the figures below:
COMMUNICATIONS
MODULE
TRIGGERING DEVICE
iGSMBR-007-V0
GND
GND
ZONE INPUT Z1/Z2
2
1
4
5
TB1
TRANSFORMER
AC INPUT 2
AC INPUT 1
+ TRIGGER
(VOLTAGE: 2-13V)
J1
BATTERY
Figure 2-4. Wiring Zone Z1/Z2 Input for a Positive (V+) Trigger
TRIGGERING DEVICE
iGSMBR-008-V0
GND
GND
ZONE INPUT Z1/Z2
2
1
4
5
TB1
TRANSFORMER
AC INPUT 2
AC INPUT 1
-
TRIGGER
(VOLTAGE: 0-1V)
NOTE:
TRIGGER VOLTAGE
IS +V TO GROUND FALLING
EDGE TRIGGER
COMMUNICATIONS
MODULE
J1
BATTERY
Figure 2-5. Wiring Zone Z1/Z2 Input for a Ground (V–) Trigger
Summary of Contents for AlarmNet GSMBR
Page 2: ......
Page 38: ...GSMBR iGSMBR Installation and Setup Guide 3 22 ...
Page 50: ...GSMBR iGSMBR Installation and Setup Guide A 2 ...
Page 54: ...GSMBR iGSMBR Installation and Setup Guide C 2 ...
Page 57: ...NOTES ...
Page 58: ...NOTES ...
Page 59: ...NOTES ...
Page 60: ...NOTES ...
Page 61: ...NOTES ...
Page 62: ...NOTES ...