C-1
Appendix C: IP Downloading
General Information
The 7847i/7847i-E
can be used to provide high-speed up/downloading to Honeywell VISTA
and LynxR-I control panels. This allows site maintenance independent of central station
monitoring, and modification to sites through an Intranet or globally via the Internet.
Residential panels that support IP downloading (e.g., Vista-20P and LynxR-I) are connected
to the unit
through the ECP bus. Currently, commercial controls such as VISTA-128BP and
FBP support IP downloading through use of a Direct Wire connection (using the trigger
cable).
UL
Downloading may only be performed if a technician is at the site.
Direct Wire Setup
To perform IP up/downloading using Direct Wire, the unit
requires that Direct Wire
downloading over IP programming is enabled (Direct Wire Y/N), and that the ECP Device
Address on which the unit
communicates with the control panel as a keypad is entered
(Keypad Address). Additionally, the 7847i/7847i-E
must be connected by cable as shown
below to the panels listed.
NOTES:
1.
For Direct Wire IP downloading on Commercial Fire panels (e.g. VISTA-128FBP,
FA1700C), Program Field
3*19
Enable J2 Header Printer Port
must be set to
"
1
".
2.
This feature is not available if device is set for zone trigger mode.
1
2
3
4
5
6
7
8
9
NU
VISTA-128BP/250BP
FA1660C
J8 CONNECTOR
VIOLET
GREY
YELLO
W
RED
GREEN
BR
O
W
N
BLUE
BLUE
WHITE
BLA
CK
IN 2
IN 3
GR
OUND
OUT 5
OUT 6
GR
OUND
GR
OUND
PRINTER DTR
K4668WH
RJ 11 CABLE
7847i-E-026-V0
TB 1
6
7
8
5
11
10
9
2
3
4
1
PROGRAMMER
PORT
4142 TR CABLE
PARTS SUPPLIED WITH DOWNLOADER KIT P/N VBPCOMKIT
7847i / 7847i-E
1
2
3
4
5
6
7
8
9
7847i-E-027-V0
INPUT 1
GR
OUND
OUT 1
OUT 4 OUT 7 OUT 3 OUT 6
OUT 2
OUT 5
VISTA-128FBP/250FBP
FA1670C /FA1700C
J2 CONNECTOR
VIOLET
GRA
Y
YELLO
W
WHITE
RED
GREEN
BR
O
W
N
BLUE
BLA
CK
6
5
4
3
2
1
+ PWR
- (GND)
RXD
not used
not used
TXD
not used
not used
BLUE WHITE
+ (TO TERM 11)
- (TO TERM 12)
RED
8
7
TO
AUX PWR 1
OUTPUT
TB 1
6
7
8
5
11
10
9
2
3
4
1
PROGRAMMER
PORT
4142 TR CABLE
4100SM
K14394LF 25-PIN TO RJ11 CABLE
PARTS SUPPLIED WITH DOWNLOADER KIT P/N VFBPCOMKIT
7847i / 7847i-E
Figure 16. Cable Connections for IP Downloading
Summary of Contents for AlarmNet 7847i-E
Page 2: ......
Page 14: ...7847i 7847i E Installation and Setup Guide 2 6 ...
Page 42: ...7847i 7847i E Installation and Setup Guide 5 4 ...
Page 52: ...7847i 7847i E Installation and Setup Guide B 2 ...
Page 56: ...7847i 7847i E Installation and Setup Guide D 2 ...
Page 57: ...NOTES ...
Page 58: ...7847i 7847i E Installation and Setup Guide NOTES ...
Page 59: ...NOTES ...
Page 60: ...7847i 7847i E Installation and Setup Guide NOTES ...
Page 61: ...NOTES ...
Page 62: ...7847i 7847i E Installation and Setup Guide NOTES ...