![Honeywell AlarmNet 7847i-E Installation And Setup Manual Download Page 26](http://html.mh-extra.com/html/honeywell/alarmnet-7847i-e/alarmnet-7847i-e_installation-and-setup-manual_148760026.webp)
7847i/7847i-E Installation and Setup Guide
3-12
Important Information Regarding Private LAN mode (7847i-E only).
1.
Prompts 12-18 apply only if Private LAN was selected in Prompt 11.
2.
Prompts 14-16 apply only if Prompt 14: Alarm Delivery is set to “Fail to CS IP2".
PROMPTS
ZONE
TRIG.
4204/
2-4204
ENTRY OPTIONS
DESCRIPTION
11
En.Priv.LAN: Y/N
(N)
✔
✔
[Y], [N]
Applies only to 7847i-E. Press [Y] to enable alarm
delivery via a Private LAN to a 7810iR-ent
receiver.
Press [N] to enable alarm delivery through
AlarmNet and go to Prompt 20: Primary City ID.
12
CS IP:
255.255.255.255
✔
✔
12
digit:
xxx.xxx.xxx.xxx
Enter the 4-part primary CS IP address of the
7810iR-ent receiver at the reporting center to
which this device will report. The four parts of
the address must be separated by spaces.
NOTE:
This entry CANNOT be left as
“255.255.255.255”. It MUST be programmed with
a valid IP address.
13
CS Port:
(80)
✔
✔
[80]
Enter the Central Station Port Number.
NOTE:
The CS Port number must match the
"Listening Port" question of the 7810iR-ent.
14
Alarm Delivery:
Only One CS IP_
✔
✔
[Only One CS
IP]
[Fail to CS
IP2]
Select the "Only One CS IP" option, if only one
Central Station IP address is desired and go to
Prompt 18: "Installation Key".
Select the "Fail to CS IP2" option, if a secondary
Central Station IP address is desired.
15
Secondary CS IP:
255.255.255.255
✔
✔
12
digit:
xxx.xxx.xxx.xxx
Enter the 4-part secondary CS IP address of the
7810iR-ent receiver at the reporting center to
which this device will report. The 4-parts of the
address must be separated by spaces.
NOTE:
This entry CANNOT be left as
“255.255.255.255” if using the Secondary CS IP.
It MUST be programmed with a valid IP address.
16
Second CS Port:
(80)
✔
✔
[80]
Enter the Central Station Port Number.
NOTE:
The CS Port number must match the
"Listening Port" question of the 7810iR-ent.
17
IP2 Supervision
30 Day_
✔
✔
•
30 Day
•
Daily
•
Full Rate
•
None
If 30 Day or Daily is selected, the 7847i-E will
send a test alarm to the second CS IP within that
interval.
If Full Rate is selected, a status message is sent
to the second CS IP at the same rate as the
regular Supervision Interval (Prompt 27).
NOTE:
The second 7810iR-ent must be
programmed to supervise subscribers in order to
generate the communication failure.
Press the [space] key to scroll through the choices.
18
Installation Key:
**********_
✔
✔
[0-9]
Enter the 10-digit Installation Key necessary for
communication with 7810iR-ent. If the key entry
is invalid, the prompt is repeated. See the
Installation Key
paragraph in
Section 1
for more
information.
Summary of Contents for AlarmNet 7847i-E
Page 2: ......
Page 14: ...7847i 7847i E Installation and Setup Guide 2 6 ...
Page 42: ...7847i 7847i E Installation and Setup Guide 5 4 ...
Page 52: ...7847i 7847i E Installation and Setup Guide B 2 ...
Page 56: ...7847i 7847i E Installation and Setup Guide D 2 ...
Page 57: ...NOTES ...
Page 58: ...7847i 7847i E Installation and Setup Guide NOTES ...
Page 59: ...NOTES ...
Page 60: ...7847i 7847i E Installation and Setup Guide NOTES ...
Page 61: ...NOTES ...
Page 62: ...7847i 7847i E Installation and Setup Guide NOTES ...