Section 4 – Programming
4-9
Using Wireless Keypads
Wireless keypads (5827/5827AP & 5827BD) can provide
another way of entering or exiting the premises. They
function the same as alpha keypads, except when the
code + # 73 is entered. This entry will allow momentary
access to ALL access points in the partition to which the
keypad is assigned. To program the wireless keypad,
enter the partition the keypad is assigned to in field
1*48.
Control of Lighting and Appliances
Lighting and appliances can be controlled when an
access or exit event occurs. Lights or appliances can be
automatically turned on or off when a valid entry or
egress request is presented at an access point. To
control these devices, the VISTA-120 relays or the ACS
relays or triggers are used with keypads and/or RF
transmitters whose response type is Access Point (27).
To program the control of lighting and appliances,
perform the following steps:
Step Action
1
Enter Output Programming in the #93 Menu
Mode.
2
Program all the information for the relay.
3
Select the output type: ECP (1) (4204/4204CF)
or (2) (X-10).
See Output Programming in the Programming Guide
for a detailed explanation.
Using the VISTA-120 for Stand-Alone Access Control
The VISTA-120 can be used for access control without
interfacing to PassPoint ACS or VistaKey. A user can
trigger an access point (i.e., door strike) for 2 seconds by
entering User Code + [0].
To program the VISTA-120 for Stand-Alone access
control, perform the following steps:
Step Action
1
Enter Output Programming in the #93 Menu
Mode.
2
Program the output type as 1, or 2.
3
For type 1, program the ECP address and
relay number.
4
For type 2, program the house and unit codes.
5
Program the relay number in field 1
∗
76
(partition-specific).
See Output Programming in the
Programming Guide for a detailed
explanation.
Programming for Panel Linking
Step Action
1
Program the Panel Link Module (PLM) into
the system in
Device Programming
in the
#93
Menu Mode
with Device Type 10
.
2
If you want to supervise the PLM,
program
zone 8xx with response type 05, where “xx” =
the module’s address. If you want the zone to
report to the central station, make sure the
report code for the zone is set with a non-zero
value.
3
If you want to supervise the PLMs
connected to other controls,
program those
modules in Zone Programming with response
type 14. Also, program the panel ID number.
The ID number must match the ID number
programmed in
Device Programming
of the
control panel the PLM is connected. If you
want the zone to report to the central station,
make sure the report code for the zone is set
with a non-zero value.
Be sure to program
the input type with 00.
See Device Programming and Zone Programming in #93
Menu Mode Programming in the Programming Guide
for a detailed explanation of the programming
procedures.
Summary of Contents for ADEMCO VISTA-120
Page 2: ...ii ...
Page 18: ...VISTA 120 Installation and Setup Guide 2 8 ...
Page 70: ...VISTA 120 Installation and Setup Guide 5 16 ...
Page 88: ...VISTA 120 Installation and Setup Guide 7 4 ...
Page 90: ...VISTA 120 Installation and Setup Guide 8 2 ...
Page 100: ...VISTA 120 Installation and Setup Guide A 2 ...
Page 104: ......
Page 106: ......
Page 113: ......